Filter Results By:
Products
Applications
Manufacturers
Spectral Response
sensitivity of sensor to a specific wavelength over a spectral band.
See Also: IPCE
-
product
Combined Illumincance and Irradiance Probe
LP471P-A
Combined probe for measuring ILLUMINANCE (lux), with standard photopic response, and IRRADIANCE (μW/cm²) in the UVA spectral range (315…400 nm, with peak at 360 nm).
-
product
Custom Detectors
Besides the described types Inphora can supply detector-filter combinations with parameters matching the customer's special requirement, with different sized housing, without housing. If the application determines the detector's spectral responsivity, we can achieve that with a filter designed exactly to the specifications. CCD cameras with unusual spectral sensitivity functions can be matched with filters to obtain CIE tristimulus response or photopic response. Similarly, photmultiplyers can be matched also with INPHORA filters. When determining parameters for a custom detector-filter combination several details have to be considered:
-
product
Extreme Low Power Detector Laser Power Meters
11XLP12
11XLP12 extreme low power detector is best suitable for low power im both the µW and mW regimes with very low thermal drift. Featuring broadband flat spectral response, minimal thermal drift and a noise equivalent power as low as 1 µW the 11XLP12 is ideally suited for measuring any pulsed or CW low power laser.
-
product
Frequency Response Function
FRF
FFT Spectral Analysis. Frequency Response Function (FRF) is a commonly used measurement type of the Dynamic Signal Analyzer. FRF is defined as the ratio of response i.e. acceleration, velocity, or displacement with respect to the excitation force which is the reference.
-
product
Illuminance Probe
LP471PHOT
Photometric probe for measuring the ILLUMINANCE, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.
-
product
Light Meters
LXP-2
The digital light meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its construction. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter.
-
product
Luminance Probe
LP471LUM2
Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°.
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
Power Probes
RkT Thermopile Series
The RkT Series thermopile power probes are ideal for measuring Nd:YAG, CO2, and other mid-power lasers. The probes are designed to withstand average power densities up to 20kW/cm2 (15MW/cm2 peak pulse power density). The flat UV to far-IR spectral response allows the probes to measure broadband sources as well. Measure the power of cw sources or the average power of sources pulsed at 5Hz or greater.
-
product
Product Range
Solus
Introducing Protea's new range of laser gas analysers - Solus. The Solus platform represents an extension of Protea's spectroscopic gas analysis equipment into laser based technology, allowing for highly selective, quick response and low range measurements of 1 or 2 gases in a cost-effective, re-configurable package. Solus utilises the latest in Tunable Laser Diode Absorption Spectroscopy (TDLAS), together with the best in micromachining technology, to deliver a precisely controlled narrow wavelength that can be tuned over a small range. The narrow linewidth allows for selection of precise spectral absorbance in the NIR region, free from cross-interferences of other absorbing gases. For some tuning ranges, a number of gases can be measured by tuning a single laser diode e.g. NH3 and H2O.
-
product
Pyranometer Negligible thermal gradient zero-offset
CMP 22
CMP 22 has all the features of CMP 21 but uses very high quality quartz domes for a wider spectral range, improved directional response, and reduced thermal offsets. Because of the high optical quality of these domes the directional error is reduced below 5 W/m. Kipp & Zonen is confident that CMP 22 is the best Pyranometer currently available.
-
product
Pyrgeometer Low Temperature dependence of sensitivity
CGR 4
CGR 4 pyrgeometer is an instrument for the highest quality scientific measurements. The specially designed meniscus dome provides a 180 field of view with negligible directional response error. A hard-carbon coating on the outside of the dome smoothes the spectral response and provides extra protection to the silicon surface.
-
product
Radiometer Spectral sensitivities precisely adapted to the human skin
UVS-E-T
The UVS-E-T has a spectral response that is adapted to the erythemal (sunburn) action spectrum of the human skin (CIE 1987 weighting). Hence, this radiometer collects information of medical and public concern: UV Index, UV Erythemal dose and dose rate.
-
product
Radiometer Spectral sensitivities precisely adapted to the measurement task
UVS-B-T
Compared to the spectral response of the UVS-E, the UVS-B-T has a sharper cut-off at the transition from UV-B to UV-A. This feature reduces the UV-A contribution to the radiometer output and permits the highest possible correlation to atmospheric UV-B irradiance.
-
product
Sensors
Renesas' light and optical sensors are best in class for ultra low light sensitivity, low power consumption, ideal spectral response, and easy to use simple output algorithms. We offer a full suite of optical sensors to suit your application requirements and budget.
-
product
SiTek Standard PSD
1L20_CP3
The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.
-
product
SiTek UV PSD
The UV PSD is a detector optimized for use in the UV wavelength region 200-400 nm, although its spectral response reaches up to 1100 nm. The sensitivity in the UV region (200-400 nm) is extremely high. The UV-PSD has the same outstanding specifications as the standard SiTek PSD.
-
product
Spectral Response (Spectral Sensitivity) Measurement
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
product
USB Smart Detector
OL 731
The OL 731 USB Smart Detector is a low-cost, hand-held radiometer/photometer that can be tailored to the spectral response of the user's specific application requirements with the use of a range of sensors and filters. Several units can be multiplexed on to one USB, and it can be programmed to read in any user-specified radiometric or photometric unit. The OL 731 is suitable for a variety of critical applications.
-
product
UV A Radiometer
UVS-A-T
The UVS-A-T has a broad spectral response optimised for precise measurements of atmospheric UV-A irradiance.
-
product
UV/IR Flame Detector
FL500
The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. This UV/IR combination provides a fast response time and increased false alarm immunity against sources of radiation for reliable protection.
-
product
Handheld Raman Analyzer
TacticID®-1064
The TacticID®-1064 is a field-ready handheld spectral analysis instrument designed for non-contact forensic analysis by safety personnel and first responders, including law enforcement personnel, bomb squads, customs and border patrol, hazmat technicians, and more. The TacticID®-1064 utilizes proven Raman spectroscopy, allowing users to get real-time actionable identification of unknown chemicals, explosives, narcotics, pharmaceutical drugs and many other substances while reducing operational uncertainty and response time. The TacticID®-1064 includes a comprehensive library of over 10,000 substances. In addition, users have flexibility to create their own libraries. By utilizing the 1064nm wavelength, the TacticID®-1064 avoids fluorescence, allowing users to get results in less than 1 minute even when working with tough street samples.
-
product
Hybrid Picosecond Photon Detectors
HPPD Series
technology.The HPPD is our latest development in TCSPC detector technology that combines the benefits of conventional PMT design (wide spectral response and large active area)with the advantages of solid state APD technology (good detection efficiency, negligible after-pulsing and exceptional temporal resolution). Hybrid detectors are becoming thefirst choice for FLIM and short lifetime determination.
-
product
Ambient Light Sensors
Renesas' ambient light sensors can adjust a display’s backlight, which improves user experience and power savings by optimizing the display’s viewability. Their ultra-low light sensitivity, low power consumption, ideal spectral response, and easy to use simple output algorithm make them best-in-class. We offer a full suite of light-to-analog and light-to-digital solutions to suit your applications requirements and budget.
-
product
Solar Energy, PV Monitoring
Apogee silicon-cell pyranometers feature a monocrystalline silicon-cell detector that has the same spectral response as a PV module. The sensors quantify shortwave radiation being harnessed as electricity.
-
product
Energy Probes
RjP-400 Series
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
Power Detector Laser Power Meters
11PMK-H5
Fast, Small Size, Flat Spectral Response, Full NIST-Traceability, High Damage Threshold: 36 kW/cm² to 45 kW/cm², Personal Wavelength Correction™, Low profile, Air and Water cooled, Energy mode, Effective aperture diameter 19 mm (area 2.84 cm²)
-
product
Complete Testing Solutions
System includes a lamp and monochromator for a tunable light source, which is coupled to a high sensitivity source meter with measurement software. This user-friendly system is the most powerful Spectral Response system currently on the market, but its true power is the ease of upgrading from the base PTS-1 to the more powerful PTS-2-QE (Quantum Efficiency) or PTS-3-CPM (Constant Photocurrent Method). Designed for researchers who have limited budgets but want to start work immediately, this allows the ability to do baseline studies until additional funding for the full QE or CPM system becomes available.
-
product
EQE/Photon-Electron Conversion Testing
Enlitech offers different solutions for incident photon-electron conversion testing systems. The available systems include IPCE, PV External quantum efficiency (PV-EQE), Internal Quantum Efficiency, Spectral Response (SR), Highly-sensitive EL-EQE. There are over 1,000 SCI papers cited Enlitech‘s systems to provide reliable experimental data for significant scientific publication. The Highest PV-EQE sensitivity and EL-EQE both reach 10-5 % (7 orders). They can be utilized to PV conversion efficiency, HJT/ PERC/TOP-CON current-loss analysis, Organic PV charge-transfer-state and Perovskite PV trap state measuring, and Organic PV and Perovskite PV Voc loss analysis.
-
product
Light Sensor
NaPiCa
Panasonic Industrial Devices Sales Company of America
Visible light sensor (Silicon Photo IC) that detects light and converts into electrical current. Consists of a photodiode and built-in amplifier. Optical filter provides spectral response similar to human eye sensitivity. Applications include: LCD Backlight Control, Commercial and Residential Lighting Brightness Control, Security Lighting.