-
product
Noise Figure Measurements With Vector Correction
S96029B
This software application enables high-accuracy noise figure and noise-power measurements of amplifiers. It utilizes Keysight’s unique vector-source-correction technique, which uses a source-impedance tuner to remove the effects of imperfect system-source match. This approach yields accuracy that surpasses that provided by the Y-factor method and other cold-source implementations, especially for in-fixture, on-wafer, and automated-test environments. A scalar-calibrated method is also available that offers less accuracy but is faster and does not require an impedance tuner.
-
product
Noise Figure Measurements With Vector Correction
S95029B
The S95029B noise figure application enables high-accuracy noise figure and noise-power measurements of amplifiers, frequency converters, and mixers by using the Keysight vector-source-correction technique. Using a source-impedance tuner to remove the effects of imperfect system-source match, this technique produces higher accuracy results than Y-factor method and other cold-source implementations--especially for in-fixture, on-wafer, and automated-test environments.
-
product
IEC61032 Test Probe 12 Figure 8
CX-12
Shenzhen Chuangxin Instruments Co., Ltd.
Test Probe 12 Figure 8 is intended to be used on appliaces for verifying the inaccessibility of hazardous live parts or hazardous mechanical parts.
-
product
Full Band Noise Figure and Gain Test Extenders
STG-06-S1
Full band noise figure and gain test extenders are offered to extend noise and gain measuring capabilities up to higher millimeterwave frequency ranges. These extenders are designed to interface with noise and gain test systems that have an input IF of 10 MHz to 1.6 GHz, such as the industry standard Keysight 8970A/B, N8975A and Maury MT 2075B. The noise figure and gain test extenders include a high-performance, solid-state noise source (STZ series) and a full waveguide down converter (STC serie...show more -
product
Noise Figure Analyzer, Multi-touch, 10 MHz to 40 GHz
N8976B
The N8976B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8976B.
-
product
Noise Figure Analyzers & Noise Sources
Keysight Technologies provide a range of noise figure measurements solutions to meet your needs, from the NFA series noise figure analyzers to the noise figure measurement personalities for our spectrum analyzers. We also have a range of noise sources to complete the measurement solution.
-
product
IEC60335-2-9 Clause 3 Figure 103 Vessel For Testing Hotplates
CX-GZ
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60335-2-9 clause 3 figure 103 Vessel for testing hotplatesParameter:1.Pot and lid material industrial aluminum2. Pot material thickness 2 mm;3. The bottom of the pot body can not be outward convex, can not exceed 0.05mm;4. Pot body and lid surface should be smooth;5, size: 110, 145, 180, 220, 300mm each one
-
product
Noise Figure Analyzer, Multi-touch, 10 MHz to 26.5 GHz
N8975B
The N8975B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8975B.
-
product
Noise Figure Analyzer, Multi-touch, 10 MHz to 7 GHz
N8974B
The N8974B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8974B.
-
product
Noise Figure Measurements With Vector Correction
S93029B
The S93029B noise figure application enables high-accuracy noise figure and noise-power measurements of amplifiers, frequency converters, and mixers, utilizing Keysight’s unique vector-source-correction technique
-
product
Noise Figure And Gain Test Extenders
SA full noise figure and gain test extender that extends the noise and gain measurement capabilities of common and low frequency signal synthesizers and noise figure meters to the frequency range of 110 to 170 GHz. This extender is designed to interface with industry standard noise and gain test systems.
-
product
Noise Figure Meters
H5M Series
*Frequency range from 10 MHz to 4/20 GHz*Noise Ratio and Gain measurements*Frequency converter measurements with a fixed or external heterodines*Built-in thermostatic YIG preselector*High measurement speed*Extend the NFA solution up to 50 GHz with special downconverter unit*SCPI Language Compatibility
-
product
Noise Figure Analyzer, Multi-touch, 10 MHz to 3.6 GHz
N8973B
The N8973B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8973B.
-
product
Noise Figure Analysis Using NI PXI RF Test Instruments
NI-RFmx Noise Figure
Measure noise figure, gain, Y-factor, effective temperatures, hot and cold power, and moreOptimized calibration and measurement routines for multi-DUT test using Y-factor and cold sourceSupports the PXIe-5668R 26.5 GHz VSA, the PXIe-5698 26.5 GHz preamplifier, and VSTsDesigned for use with industry-standard noise sources such as the Noisecom NC346 Series
-
product
60 GHz Noise Figure Test Set
The Noisecom 60 GHz Noise Figure test set has 4 separate systems designed to perform Y-factor noise figure measurements using a high performance Spectrum Analyzer or a dedicated receiver. Each system contains a highly stable V-band noise source, isolator(s), optional waveguide to coaxial transitions and an optional pre-amplifier for use with a spectrum analyzer. The two standard calibration tables have ENR data points at 1 GHz intervals.* System ENR is measured before the DUT connector and at the final output stage allowing for pre-test calibration of the system.
-
product
Noise Figure Measurements With Vector Correction
S97029B
The instrument’s standard receivers are used for noise figure measurements with the S97029B. An external preamplifier and filter(s) is required for devices with < 30 dB of excess noise (gain plus noise figure in dB)
-
product
Noise Figure Analyzers
NFA Series
Optimize for noise figure using the NFA Series of high performance noise figure analyzers, which are designed to make fast, accurate, repeatable measurements. Key features include the simple user interface, graphical display, data storage, selectable bandwidths and on screen limit lines for pass/fail testing. With the NFA Series reliable measurements up to 40 GHz are now available in a single instrument.
-
product
IEC60335-2-9 Clause 3 Figure 104 Vessel For Testing Induction Hotplates
CX-104
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60335-2-9 clause 3 figure 104 Vessel for testing induction hotplates Parameter : Pot and lid material is mainly Q235, carbon mass fraction <0.08%; 2. The thickness of the wall material is 2 mm;3. The bottom of the pot body can not be outward convex, can not exceed 0.05mm; 4. Pot body and lid surface to be clean 5, size: 110, 145, 180, 220, 300mm each one

















