Filter Results By:
Products
Applications
Manufacturers
Microphone Calibration
an accurate sound units of measure to facilitate comparison to and adjustment of instruments.
See Also: Microphone Calibrators, Sound Calibration
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
ICP Microphone System
378C10
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
ICP Microphone System
378A14
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Measurement Microphones
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
product
Microphone System
378B02
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Multichannel Acoustic Calibrator
WK-8
Multichannel Acoustic Calibrator Type WK-8 is designed for calibration of multichannel acoustic measurement systems equipped with a half-inch measuring microphones in the field conditions.
-
product
Noise Dose Meters
Here you will find a full range with an industrial standard noise dose meter to suit every requirement. With the portable noise dose meter you can carry out measurements quickly to gain control of a situation or to set the device to take timed measurements. The noise dose meter is important for all industries, especially by using it as a mobile device which is able to assess office stress levels or street noise levels.Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10pm in excess of what local laws permit. We, of course, can assess which noise dose meter you require in relation to the issue you have and the relating laws. We also have microphone extension cords, tripods, calibrators and calibration certificates for most models of noise dose meter.
-
product
Noise Meters
Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.
-
product
PC based USB Real Time Analyzer
1) Measurement microphone and its accessories (a windshield and a microphone clip)2) XLR-to-USB Converter3) USB cable (1.5 m) 4) CD (contains the copy-protected Multi-Instrument Software) 5) USB hardkey (contains a Multi-Instrument Standard License)6) Audio Test CD (contains a list of audio test tones and noises) (AudioTestCD.zip or AudioTestCD.rar)7) 1/8” TRS cable (1.8m) 8) Black Soft Pouch Case 9) Individual Sound Level Calibration Data 10) Individual Microphone Calibration Data (only provided in RTA-168B)11) A small microphone stand
-
product
Sound Level Calibrators
PeakTech Prüf- und Messtechnik GmbH
For sound level measurements in extreme conditions, at high altitudes or high demands on the accuracy of the measurement results, sound level meters should be checked prior to the measurement with a sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed frequency characteristic. This calibrator has two switchable calibration steps.
-
product
Sound Level Meter, 35 dB, 130 dB, 5 dB, 0.1 dB, 0 °C, 50 °C
72-6635
*Large LCD Display, easy to read*Characteristic of "A" frequency weighting network are designer to meet IEC 651 type 2*Fast time weighting characteristic mode*Build in adj. VR is available for easy calibration*Condenser microphone for high accuracy & long-term stability*Hold function to freeze the display value*Warning indicator for over and under range*LCD display for low power consumption & clear read-out even in bright ambient light condition*Durable, long-lasting components, including a strong, light weight ABS plastic case*Small and light weight design allow one hand operation*Low battery indicator*High quality with economical cost
-
product
SPL Calibrator -124 dBSPL @ 1 kHz
511ES124
The 511ES124 is designed to provide 124 dBSPL at 1 kHz to meet the needs of the low sensitivity microphones found in many high SPL measurement applications. The microphones used in Car Stereo competitions like dB Drag racing, IASCA, and USAC have had their sensitivities reduced to the point where 94 dBSPL may no longer be adequate for calibration.
-
product
ultimate measurement microphone
cm-145
The CM-145 is a very low noise, flat frequency response, omni-directional microphone built to IEC651 Type 1 standards and comparable to the B & K 4006. This is an electret condenser microphone with a 1/2 diaphram of nickel-copper alloy. Included with the microphone is a shock mount, foam lined wood storage box and individual calibration chart.
-
product
Acoustic Calibrator
CAL150
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
product
Acoustic Calibrator
CAL250
The Larson Davis Model CAL250 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
product
Compression Unit
BK1611
The BaKo BK1611 is a Compression Unit that uses a real time feedback loop to create a frequency sweep with constant level output. This would normally be used for either research or for calibration rather than product line testing and is useful because of its extreme stability. The BK1611 is not a dedicated system so it can be integrated into a variety of systems to be used for microphones, speakers or vibration motors.
-
product
Microphone Calibration Workstation
9350C
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
product
ICP Microphone System
HT378B02
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
product
ICP Microphone System
378C01
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
product
Electret Measurement Microphone
EMM-6
The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.
-
product
Handheld Audio Analyzer
PAA3X
The PAA3X is a highly accurate handheld audio analyzer that gives sound engineers a rich array of sound analysis tools. The system features both 61-band and 31-band real time spectrum analysis, RT60 reverb time measurement, SPL and line meter, internal signal generator, EQ setting program, microphone calibration and speaker phase checking abilities. All functions and menus can be accessed through a central jog dial, leaving your other hand free to adjust audio settings. The large color LCD screen has an adjustable brightness to help you see in a dark or well-lit environments alike. The PAA3X also features a "screen capture" function allowing users to save images of the screen to an SD card in BMP format for later reference. The detachable precision microphone can be placed remotely via the included 5-meter extension cable, offering flexible on-site operation management. With all this plus a built-in rechargeable lithium-ion battery, the PAA3X is a must-have multifunctional tool for all serious audio engineers.
-
product
type 1 ios test and measurement microphone
iprecisionmic
iPrecisionMic is the only Type 1 certified microphone that is also an iOS direct-connect Lightning accessory. iPrecisionMic is factory calibrated to +/-0.1dB using a NIST traceable pressure-compensated calibrator. The calibration offsets are store in the microphone's nonvolatile memory, and are transferred automatically to an iOS device running our AudioTools app.
-
product
Calibration Systems
Brüel & Kjær Sound & Vibration A/S
Our calibration solutions meet the broad variety of needs for calibration in the field of sound and vibration accurate primary and secondary calibration of measuring equipment and the scope of transducers: accelerometers, microphones and hydrophones.
-
product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
Portable, self-contained, high-intensity acoustic microphone calibration source
-
product
Precision Sound Level Calibrator
CAL200
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
product
Analoge Sound Level Meter
Model KM-20/ YF-20
Kusam Electrical Industries Limited
• One-handed simple, easy to operate.• Inbuilt reference signal.• Inbuilt battery test.• Quickly, accurately measures sound level.• Compressed scales minimise range switching.• An internal reference signal is available for checking the meter’s operation.• Calibration Check• Microphone with Capacitance Microphone.
-
product
Sound Level Calibrator
TM 100
Kusam Electrical Industries Limited
• Standard : Confirms to IEC 942 Class 1.• Output Sound Level : 94dB and 114dB under reference.• Accuracy : ±0.3dB (20°C, 760 mm Hg)• Frequency of 1000 ± 0.1% Hz allows calibration with A / B / C or D weighting networks or linear.• Low Battery Indicator (LED).- Operating Temperature range : -10 ~ +50 C- Storage Temperature range : -40 ~ +65 C (with batteries removed).- Temperature Coefficient : 0 ~ 0.01 dB / C• Calibration of “1 and ½” ceramic microphones.• Altitude Effects : Approx. 0.1 dB decrease for each 2000 feet increase in altitude fromsea level to 12,000 feet elevation, or comparable atmospheric pressure change(approx. every 50 mm of Hg decrease).• Battery : Single 9V transistor Battery. (NEDA 1604)• Battery Life : Approx 100 hours.• Dimension : 48 x 48 x 138mm