Filter Results By:
Products
Applications
Manufacturers
Luminous Intensity
Amount of light emitted from a given direction.
-
product
Datalogging Light Meter (RS-232)
DLM 536
Spectrum of photo sensor meets C.I.E. photopic curve V(l). 16000 Records Data logging capacity. RS-232 interface (software included). Measurement of luminous intensity(PC Software)
-
product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1800BCCD
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
LED Luminous Intensity Distribution Tester
LS860
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.
-
product
LED Optical Meters
Measure the optical characteristics of white LEDs and LED lighting during production. Measure Luminous Intensity, Chromaticity, and Color Rendering Index
-
product
Light Intensity Sensor
ENVIROMUX-LIS
Detects and measures the luminous intensity of light. Ideal for monitoring unmanned closets, telecom rooms, remote data rooms, or other low traffic facilities. Applications from 0 to 128,000 lux. Human eye response (540 nm peak sensitivity). IR and UV rejection. RJ45 connector. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS. Compatible with ENVIROMUX-2D/5D/16D.
-
product
Lux Meters
Shenzhen Everbest Machinery Industry Co.,Ltd.
Unit of illuminance and luminous emittance, measuring luminous flux per unit area. It is equal to one lumen per square metre. In photometry, this is used as a measure of the intensity, as perceived by the human eye, of light that hits or passes through a surface.
-
product
Near Field Moving Detector Goniophotometer
LSG-1900B
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
product
Rotation Luminaire Goniophotometer
LSG-1800
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Photometers & Colorimeters
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
product
Optical Meters
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
product
Lux Meters
Lux meter is used for measuring illuminances in work places.The lux is the SI unit of illuminance and luminous emittance. It is used in photometry as a measure of the apparent intensity of light hitting or passing through a surface.
-
product
Near-field Goniophotometer
RiGO801
TechnoTeam Bildverarbeitung GmbH
Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
Goniophotometer
GMS2000
In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.
-
product
Total Luminous Flux Measurement System
This system enables the total luminous flux measurement of luminous intensity distribution 2 and 4 light sources based on the measurement standards of LED lightings LM-78 and LM-79 approved by IESNA (Illuminating Engineering society of North America) .
-
product
Goniophotometer Test System For Led Lamp
1680A 1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341,the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
Goniophotometer Test System For Led Lamp
LCG-1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
LED Goniophotometer for Lamps
880
Shenzhen Chuangxin Instruments Co., Ltd.
Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.
-
product
LED Goniophotometer For Led Tester
CX-880
Shenzhen Chuangxin Instruments Co., Ltd.
880 LED Test machine is used to measure: 1.the luminous intensity dirstribution curve, 2.intensity data, 3.spread angle and equivalent luminous flux of small lamps.
-
product
Beam Pattern Measurement System
BP100
The BP100 is purpose-made for luminous intensity measurement of lamps, using a diffusely transmitting screen to provide a flat image that can be measured by an imaging photometer. This is a low cost, versatile solution in comparison to the traditional method of measuring lamp properties as a function of angle of emission, using Goniometers that are often costly and dedicated for one specific measurement.
-
product
System Flash Meter
SF 105
Computer controlled measurement equipment to measure the time response of illuminance or luminous intensity when illuminated with rapidly changing values, e.g. flashes.
-
product
Compact Goniophotometer
LSG-1200A
The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System
-
product
Imaging Colorimeters and Photometers
Imaging colorimeters and photometers of the ProMetric® series are calibrated to replicate human response to brightness, color, and scatter. The ProMetric® Imaging colorimeters and photometers are cooled CCD-based camera systems designed to make precise, spatial measurements of luminance and chromaticity.The spatial measurement capabilities are luminance cd/m², radiance W/m², illuminance lux, irradiance W/m², luminous intensity candela, CIE chromaticity coordinates, L*a*b color scale, correlated color temperature, dominant wavelength.
-
product
Imaging Colorimeters
Westboro Photonics offers high resolution, high performance imaging colorimeters to meet the needs of manufacturers for several key applications: Computer and cell phone keyboards: automatic measurement, identification and pass/fail analysis for luminance and chromaticity of backlit glyphs and other lit elements. Beam pattern analysis of the luminous intensity distribution of lamps and LEDs. Avionic light plate panel balancing. Transportation, architectural and municipal lighting and signage.
-
product
Aging and Optical Attenuation Tester
LS822
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
product
Absolute Luminous Flux Integrators
Photometric Solutions International Pty Ltd
The Absolute Luminous Flux Integrator (ALFI) is a special device for absolute measurement of the luminous flux output of lamps. It can also to measure the luminous intensity distribution of small lamps and luminaires.
-
product
Reflex Reflector Measurement Systems
Photometric Solutions International Pty Ltd
The measurement setup involves using a projector to illuminate the test item, and then measuring the luminous intensity of the light reflected from the test item. The ratio of the luminous intensity emitted by the reflector (in candelas) to the illuminance on the reflector (in lux) is the coefficient of luminous intensity or CIL (cd/lx).
-
product
Motor Vehicle Headlight Testers
Foshan Analytical Instrument Co, Ltd.
It can be used to promptly and accurately measure the luminous intensity and the illuminating position(or the optical axis deviation amount) of the high/low beam of vehicle headlight. With the lamp image alignment techique the single-machine high/low beam testing needs only 30-odd seconds.It is also used for the dual-lamp test at the testing station,the dual-machine test at the same time needs only 20-odd seconds.