- LBA Group, Inc
product
Lightning Masts
PLP- 32
PLP- 32 Lightning Masts are recommended for a wide range of lightning protection applications where it is impossible or undesirable to attach conventional lightning terminals. Other models in the series share the same attributes and differ only in height and weight.PLP-32 Lightning Masts provide a cone of protection within which lightning charges are diverted to the mast and grounded instead of to the protected object. Multiple PLP-32 masts may be used to protect extended areas. Protected areas ...show more -
product
Integrating Spheres
Artifex Engineering GmbH & Co. KG
We offer integrating spheres made from a special polymer suitable for the wavelength range 250nm – 2.5 µm. For longer wavelengths in the range 700nm – 20 µm, a gold coating on a rough, metallic surface is used. Since lasers in this spectral range are usually also high power, we use solid copper as a thermally conductive substrate material. By choosing the size of the integrating sphere, the overall sensitivity of the system can be adjusted. In addition, the detector is independent of inhomogeneities in power density and polarization. The detector is also independent of the incidence location and angle of the laser radiation.
-
product
Sphere Spectrophotometers
Ci6x Family
The Ci6x family of sphere spectrophotometers from X-Rite are convenient handheld instruments that easily adapt range of workflows and accurately color measure a broad array of materials.
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Integrating Sphere Coating
SP-80
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
product
Portable Sphere Spectrophotometer
6085
The Elcometer 6085 is an affordable sphere spectrophotometer, designed to give fast, precise and accurate colour measurement information on materials ranging from paper and paint to plastics and textiles.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
*High Speed, Multifunctional Integrating Spheres
Multifunctional integrating spheres enable simultaneous measurement of multiple laser parameters including:*Power*Pulse Characteristics*Spectrum
-
product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
product
Integrating Spheres
All our spheres can be coupled to our high performance spectroradiometer systems for UV-visible-IR spectral power distribution measurements yielding full colour information including colour rendering indices, chromaticity co-ordinates, colour temperature, etc. Alternatively precision photometric detectors can be fitted for direct total lumen output measurements.
-
product
Integrating Sphere Systems
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
product
Azure Sphere
Comprehensive IoT security solution—including hardware (crossover microcontroller), OS, and cloud components for IoT device security—to actively protect your devices, your business, and your customers. With billions of new devices connected each year, it's more important than ever to secure yours. Help protect your data, privacy, physical safety, and infrastructure with Azure Sphere. It's built on decades of Microsoft experience in hardware, software, and cloud services to provide a turnkey security solution for IoT devices.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
Integrating Spheres For UV
Konica Minolta Sensing Americas, Inc
Instrument Systems offers complete measurement solutions for UV-A, -B and -C radiation starting from 200 nm. The operation of the well-proven Instrument Systems spectroradiometers, e.g. CAS series, with integrating spheres made from PTFE facilitate high sensitivity measurements of UV radiant flux.
-
product
Integrating Sphere Solutions
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
product
High Power Optical Head With Integrating Sphere
81628C
The 81628C High-Power Optical Head features an integrated sphere that enables it to handle power levels up to +40 dBm (with heat sink), across 800 nm to 1700 nm wavelength range. It provides the highest accuracy at high power within the family.
-
product
New Design 3m Electric Integrating Sphere
IS-3.0MA
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.
-
product
Spectrophotometer & Integrating Sphere Test System
LPCE-1
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ)...show more -
product
Test Sphere Probe
CX-500
Shenzhen Chuangxin Instruments Co., Ltd.
Test Sphere Probe This sphere is intended to verify the degree of protection of enclosures for an IP2 Code per IEC 529. Sphere is hardened steel with chrome finish. TOP
-
product
Diffuse Reflectance Sphere
DRS100
Mobile displays are used in a variety of ambient lighting environments. The evaluation of mobile displays under diffuse illumination conditions is critical to the understanding of display performance in the real world, as mobile displays are used in a wide range of ambient lighting environments. The DRS100 is purpose-made to completely characterize the diffuse reflectance properties of mobile displays, providing uniform hemispherical illumination.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of inte...show more -
product
Benchtop Sphere (d/8°) Geometry Spectrophotometers
Hunter Associates Laboratory, Inc.
Diffuse d/8° benchtop sphere spectrophotometers are recommended for transmittance color and haze measurements of transparent liquid and solid samples, and color measurements of opaque samples where it is desired to negate the effects of sample gloss and texture, as is necessary in the color formulation process when determining the effect of pigment variations irrespective of surface characteristics.
-
product
UDT-Series Integrating Sphere Systems
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
product
Integrating Spheres
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
product
Integration Spheres
Offers a wide range of integration spheres (0.25m to 3 m diameter) and spectrometer options, application-specific modules as well.
-
product
Integrating Sphere
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Integrating Sphere With Holder Base
IS-*MA
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
product
Transmission & Integrating Sphere FT-NIR Spectrometer
QuasIR™ 4000
The QuasIR™ 4000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.