Filter Results By:
Products
Applications
Manufacturers
Goniophotometers
measure the spatial distribution of sources of light.
See Also: Goniometers, Integrating Spheres
-
product
Goniophotometer
A device used for measurement of the light emitted from an object at different angles
-
product
Goniophotometers
Goniometer has the capability not to only fit into almost every optical laboratory, but also to provide measurement data on concise level. The type C set up of this instrument enables the developer of single LEDs, LED modules or chips to study angular performance in many development stages; fast and most important: reliable. The detector head of the goniometer is a high-quality, visible-range spectrometer, equipped with diffuser optics to collect all important measurement quantities over the customer required angular range. With a maximum allowable source sample size of 300mmx100mm and 25kg, the new benchtop goniometer covers a wide range of LED measurement requirements. The footprint of the instrument itself with 1.65mx0.60mx1.73m allows the usage also in small dark rooms and optical laboratories.
-
product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
LIMES 2000
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
product
Near Field Moving Detector Goniophotometer
LSG-1900B
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
product
Rotation Luminaire Goniophotometer
LSG-1800
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
LM-79 Moving Detector Goniophotometer
LSG-5000
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
product
Near-field Goniophotometer
RiGO801
TechnoTeam Bildverarbeitung GmbH
Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
Retroreflectometer
RC 100
Instrument Systems Optische Messtechnik GmbH
The RC 100 Reflex Checker was specifically developed to for testing the retroreflecting characteristics of retroreflectors used in the automotive industry. The main area of application is for adjusting and monitoring injection-molding machines in production control. That way, the RC 100 is capable to replace time-consuming measurement with goniophotometers and retroreflectometers in a photometric laboratory.
-
product
Goniophotometer
GMS2000
In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.
-
product
Goniophotometer Test System For Led Lamp
1680A 1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341,the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
Goniophotometer Test System For Led Lamp
LCG-1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
Compact Goniophotometer For Lamp Spread Angle Tester
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometrc System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
product
Light Distribution Photometer Goniophotometer
LCG-1600
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometeric System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
product
LED Goniophotometer for Lamps
880
Shenzhen Chuangxin Instruments Co., Ltd.
Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.
-
product
Goniophotometer For Luminaries Intensity Distribution Curve
LCG-1800
Shenzhen Chuangxin Instruments Co., Ltd.
Mainly used to measure FL etc. When installing luminaires, the lighting center of luminare and the rotating center of rotating table shall be at the same position. In B- coordinates, luminaire axis is superposed with the horizontal axis of rotating table. In A- coordinates, luminaire axis is vertical with the horizontal axis of rotating table.
-
product
LED Goniophotometer For Led Tester
CX-880
Shenzhen Chuangxin Instruments Co., Ltd.
880 LED Test machine is used to measure: 1.the luminous intensity dirstribution curve, 2.intensity data, 3.spread angle and equivalent luminous flux of small lamps.
-
product
Photometer
DSP 10
Instrument Systems Optische Messtechnik GmbH
The preamplifier of the DSP 10 photometer was specially developed for fast “on-the-fly” measurements with the AMS and LGS series of goniophotometers from Instrument Systems. Spatial light distribution can be measured in a fraction of the time needed with conventional systems.
-
product
GONIOPHOTOMETRY
Goniophotometers are required to measure angular resolved distributions of photometric or colorimetric quantities, either by rotating the lighting device under test or by moving the sensor around the device. Depending on the application, different geometries are used to obtain distributions in the appropriate CIE coordinate system.
-
product
Goniophotometer for Traffic Signal Lamps
LSG-1950S
LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation
-
product
Compact Goniophotometer
LSG-1200A
The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System
-
product
Goniophotometers
Instrument Systems Optische Messtechnik GmbH
All goniophotometers are designed as Type C with a horizontal alignment of the optical axis (turning luminaire configuration). Each goniometer sets benchmarks in its class for precision, reliability and handling. If these goniophotometers are combined with a spectroradiometer from Instrument Systems, they are able to determine not only photometric data but also spectral quantities, such as color coordinates, color temperature, and even color rendering index as a function of angle.
-
product
Goniophotometer
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
This system uses the method of fixing the detector and rotating the lamp under test to measure the light intensity distribution of the light source or lamp under test in all directions in the space. The main shaft and the lamp shaft adopt the conductive slip ring with precious metal fiber point brush structure, which can run 360 degrees continuously without backlash for measurement. There is no need to rotate back and forth to prevent winding and never winding. According to the requirements of the measuring lamps, the system can be configured as a double-column B-β test scheme or a single-column C-γ test scheme. Used for LED lamps (semiconductor lighting), road lamps, floodlights, indoor lamps, outdoor lamps, etc. and LED, energy-saving lamps, fluorescent lamps, incandescent lamps, HID lamps and other light sources of spatial luminosity distribution
-
product
Automotive And Signalling Goniophotometers
Photometric Solutions International Pty Ltd
PSI offers a diverse range of Automotive and Signalling Goniophotometers. These operate in the CIE A/alpha coordinate system, and are used to measure and evaluate devices such as:
-
product
General Lighting & Luminaire Goniophotometers
Photometric Solutions International Pty Ltd
These are Type C/gamma goniophotometers with wide-ranging applications including luminaires, floodlights, streetlights, LED clusters, emergency lighting, flat panel displays and others. These goniophotometers typically have an angular accuracy of better than 0.1°, which is perfect for LED and luminaire goniophotometry. The control software that comes with each system has advanced functions that make testing easy – even for inexperienced users. Additionally, the report generator and other software utilities that are also supplied make these systems powerful and advanced research and development tools.
-
product
Instrument Systems Goniophotometers
Konica Minolta Sensing Americas, Inc
If you need assistance measuring angle dependent spectral measurements, Instrument Systems has developed a comprehensive line of goniophotometers to meet your needs. Instrument Systems Goniophotometers are used to analyze angle dependent spatial radiation properties of SSL lamps and LED modules.