Filter Results By:
Products
Applications
Manufacturers
-
product
CE Marking
Only safe, flawless, and quality goods should be available on the European market – at least, that’s the objective of the CE mark. The mark proves that the product in question conforms to EU health and safety standards, whether it's toys or construction machines. Our experts conduct an audit on your products based on the appropriate EU regulations, such as the low-voltage or electromagnetic compatibility directive. Your CE declaration of conformity means your product now has right of way onto the European market.
-
product
Complete Environment for Computational Electromagnetics
CEM One
The consolidated solution emphasizes a coupling and hybridization strategy, extending much beyond previous limits with larger models, higher operating frequencies, and more sophisticated scenarios, taking electromagnetic modeling one step further. Specialized in EMC & EMI analysis with Cable Networks,k Antenna placement and radar signature.
-
product
Data Acquisition and Analysis Software
Magnifi®
Eddyfi® Magnifi® is a constantly evolving, integrated electromagnetic inspection data acquisition and analysis software. It boasts an intuitive graphical user interface (GUI) suited to modern devices, powerful reporting functions and data management, as well as simple inspection configurations.
-
product
Digital I/O Board, 64 Optically Isolated I/O Channels, 24V
APCI-1564
32 bit, 33 MHz, PCI interfaceInput channels32 isolated digital input channels, 24 V, incl. 16 interruptible and 3 fast counter inputsInput channels organised in 4 groups of 8 channels, each group has its own ground lineVoltage reversal protectionAll inputs are filteredOutput channels32 isolated digital output channels, 10 to 36 VOutput current per channel 500 mAWatchdog for resetting the outputs to "0"After power/ON the outputs are reset to ì0îShort-circuit current for 16 outputs ~ 3 AShort-circuit current for 32 outputs ~ 6 AShort-circuit current per output ~1.5 AElectronic fuseOvertemperature and overvoltage protection24 V power outputs with protection diodes and filtersSpecial output capacitors minimise electromagnetic emissionsExternal 24 V supply screened through a protection circuitryShutdown logic when the external supply voltage drops unter 5 V
-
product
Digital Transmission
The physical transfer of data (a digital bit stream or a digitized analog signal[1]) over a point-to-point or point-to-multipoint communication channel. Examples of such channels are copper wires, optical fibers, wireless communication channels, storage media and computer buses. The data are represented as an electromagnetic signal, such as an electrical voltage, radiowave, microwave, or infrared signal.
-
product
Dual Accelerometer
M7
*Dual independent Accelerometers for Quality Assurance*Protected against electromagnetic interference (EMI)*Protected against moisture*Input polarity protected*Output short circuit protected*Withstands up to 2000 g's without damage
-
product
Electromagnetic Ammeters And Voltmeters Fb-1, AC Electric Current, AC Voltage
ELECTROMAGNETIC DEVICES FOR MEASUREMENT OF ACTIVE VOLTAGE AND ACTIVE CURRENT.
-
product
Electromagnetic Environmental Effects
EEE
Electromagnetic Environmental Effects Services provides engineering design and test implementation for Electromagnetic Interference and Compatibility (EMI/EMC), along with TEMPEST capabilities certified under the National Security Agency (NSA) TEMPEST Endorsement Program.
-
product
Electromagnetic Field Detector
LCD display3 Digits LCD With 1999 Counts Low Battery Display On LCD Overload"OL" Display On LCD Accuracy(3%+3dgt) at 50Hz./60Hz. Frequency Response30Hz~400Hz Sampling RateApprox. 2.5 times/sec. Max Hold / Data Hold Battery9V x 1 Specifications0.1~200mG (milli Gause)
-
product
Electromagnetic Simulation Software
Wave3D CMD
Wave3D CMD 'command-line' controlled suite of tools is designed for large-scale parametric modeling of electromagnetic phenomena using High-Performance Computing (HPC) facilities and Cloud computers. The package utilizes the same computational engine based on MLFMA aided Moment Method solution of the Surface-Volume Integral Equation as the Wave3D CAD package. Method of Moment analysis with multilayered media Green's function enables efficient analysis of wide range of 3D planar applications such microstip antennas, microwave circuits, and interconnects.
-
product
EMC
We will guide you through items that realize low-cost electromagnetic wave shielding measures (electromagnetic wave shielding: RF shielding), which is an issue at product development sites.
-
product
EMC/EMI
American Environments Co., Inc.
ElectroMagnetic Compatibility/ElectroMagnetic Interference
-
product
EMC Tests
Electromagnetic compatibility (EMC) must be demonstrated for all devices with integrated radio components for approval in almost every country in the world. EMC tests examine whether the electromagnetic emissions from your product are within the specified limits and whether your product and its functionalities themselves are not negatively influenced by electromagnetic emissions. We offer EMC tests for modules and end products with integrated radio technology as well as IT and IoT products. Our accredited EMC test laboratories are equipped to test almost all modern radio technologies, and our EMC experts have many years of experience in this area. With us, your modern radio products are on the safe path to the global market.
-
product
EMF Exposure Test
sXcTEM835
Tests radiofrequency electromagnetic field exposures from mobile communication devices operating in the 900 MHz region (additional frequencies upon request). The setup is based on two Crawford TEM cells that are blindly excited by a fully computer-controlled signal unit.
-
product
EMF Measurements/EM Measurements/Electromagnetic Radiation
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.
-
product
EMI/EMC for Electrically-Large Platforms
XGtd®
XGtd is a general purpose ray-based electromagnetic analysis tool for assessing the effects of a vehicle or vessel on antenna radiation, predicting coupling between antennas, and predicting radar cross section (RCS). It is ideally suited for applications with higher frequencies or very large platforms where the requirements of a full physics method may exceed available computational resources.
-
product
Ethernet Switches
The switches CXR Carrier Ethernet CE 2.0 allow easy and economical transition to 10 Gigabit Ethernet class operator while providing hardened features in temperature and electromagnetic immunity.
-
product
Exposure Systems
sX series
Exposure systems are equipment or systems designed for the assessment of, for example, health risk, efficacy of therapies or mechanisms associated with exposure to electromagnetic fields. The systems designed by the IT''IS Foundation are the sX series, where sX stands for "System for eXposure" with options for cells (c), vertebrates (v), and humans (h).
-
product
Fiber Optic Rotary Joints
Fiber Optic Rotary Joints ensure flawless high-speed data transmission even in environments with strong electromagnetic interference. They are a maintenance-free alternative that eliminates friction and/or heating between rotating and stationary components.
-
product
Field Simulation Software
QuickField™
QuickField™ is a very efficient Finite Element Analysis package for electromagnetic, thermal, and stress design simulation with coupled multi-field analysis.
-
product
Full-wave three-dimensional analysis software
EZ-FDTD
Based on the Finite-Difference Time-Domain method, EZ-FDTD brings the full power of electromagnetics to solve complex EMI/EMC real-world problems for any frequency ranges that your application demands. Eliminate guessing for critical problems. Eliminates rule of thumb uncertainty. Provides insight, confidence and solutions.
-
product
Handheld 1-D electro-magnetic current meter for rivers
AEM1-DA
AEM1-DA is a 1-D electro-magnetic (EM) current meter for the flow measurements in rivers, streams and various waterways. The measurement range is 0 to 5m s-1. The EM sensor can accurately measure water speeds at a shallow depth of 3cm. The display unit has a 2MB flash memory so that the data are saved with calendar information (up to 255 station data). In comparison with conventional propeller-type current meter, AEM1-DA is robust and extremely easy to be operated and maintained.
-
product
Handheld 2-D EM current meter with temperature and depth sensor
AEM213-D
AEM213-D electro-magnetic current meter with a display unit can provide the 2-D current speeds in real time. The instrument has a depth and a temperature sensor as well as the current sensor, enabling reliable current measurements at the desired depths. The compact and light-weight unit is easily portable, allowing you to use the instrument in a variety of situations.
-
product
HDMI Over Fiber Transmitter and Reciever
QuestTel''''s HDMI Transmitter and Reciever singlemode extender over fiber optic cable integrates HDbitT technology in one standalone kit, it allows you to transport HDMI 4KX2K - 25/30Hz signal up to 20km from the source device to destination display using SC connectors.This HDMI extender supports IR back transmission function. It features with low signal loss and tolerance for electromagnetic interference.
-
product
High Frequency Transformers
Osborne High Frequency Transformers are isolation transformers and auto-transformers that operate at frequencies higher than 50/60 Hertz. Osborne recommends high frequency operation for certain applications that demand a significant reduction of the physical size of electromagnetic components. Osborne helps our clients take advantage of higher frequency designs by identifying and accommodating (or preventing) high frequency loss characteristics, such as skin-effect losses, proximity effect losses and stray losses.
-
product
Horn Antenna
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
product
Inductive Heater
BD-1.01
The device is assigned to heat the bars to the state, which allows upsetting. The DB-1.01 heater characterizes especially high watt-hour efficiency (bigger than 98%) thanks to suitable concentration of electromagnetic field in the heating zone of inductor (the solution secured by patent). It is possible to addapt the nductive heater BD-1.01 for heating any others bars.
-
product
Inductive Sensors
Inductive Proximity Switches, self contained, depend on the output of an oscillator for their operation. The oscillator resonant circuit uses an open core coil to produce a concentrated high frequency electromagnetic (RF) field, which emerges from the active surface of the sensor. If a metal target (or other electrically conductive material) enters this field, eddy currents will be induced in it, causing the resonating oscillator to be damped.
-
product
ITA, I1, EMI Shielded, With Protective Cover
410128102
The i1 EMI has many of the standard features of the i1, in addition to Electro-Magnetic Interference (EMI) protection. The EMI shielding effect on the i1 EMI ITA is provided by the stainless steel fibers in the removable plastic cover and threaded metal coupling adapter.