Filter Results By:
Products
Applications
Manufacturers
Charge Plates
acts as a capacitor whose discharge is measured.
-
product
Charge Plate Monitors
Our charge plate monitors the voltage of the battery and the voltage of the battery.
-
product
Field Meter
EFM-022
• This electrostatic field meter EFM022 is a hand-held field meter for precise measurement of electrostatic charges.• With the CPS022 accessory, the electrostatic field meter can be used as a charge plate monitor.• Precise measurement of static charges with automatic distance conversion (choice of 5 pre-set distances)• Operates on battery that can be supplemented with an AC net adaptor• With optional CPS022, can be used as a charge plate monitor for audit purposes and checking of ionization appliances
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Electrostatic Field Meter - Hand Held Field Meter for Locating and Measuring Electrostatic Field Density
PFM-711B
- Lightweight, portable, hand-held Field Meter- Measure in 1 volt/in increments 0 to ±1,999 Volts- Measure in 10 V/in increments 0 to ±20,000 VoltsAccuracy of <±5%- LED ranging lights help position the meter at the right distance- Zero button allows the display to be adjusted to zero (0)- Hold feature freezes the measurement on the display- Use with Prostat CPM-720B Charge Plate Monitor and PCS-730B Electrostatic Charger- Use with Prostat PGA-710B AutoAnalysis System or X-Y Plotter- Analyze Footwear/Flooring Combinations- Verify Ionizer Balance and Decay Time Performance- 2-year Limited Warranty (1 year on the sensor)
-
product
Ionization Test Set
PFK-105
- Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included
-
product
Basic Field Kit
PFK-101
The PFK-101 includes the PFM-711B Electrostatic Field Meter, CPM-720B Charge Plate Monitor and PCS-730B ±1 kV Electrostatic Charger for measuring ionizer decay and balance.
-
product
Electrostatic Discharge
Our electrostatic discharge (ESD) measurement and control solutions include charge plate monitors, sensors, resistivity meters, and voltmeters. Reliably monitor, measure, locate, and test for static electricity.
-
product
Electrostatic Products
We offer electrostatic measurement instruments for electrostatic discharge (ESD) and high-performance applications. Select from our reliable electrostatic sensors and detectors, voltmeters, charge plate monitors, and surface resistance/resistivity meters.
-
product
Charge Plate Monitors
Our easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing.
-
product
Collapsible 6 Inch Charge Plate Monitor Assembly
CPM-760A
- 6" x 6" (15 cm x 15 cm) conductive plate- Total system capacitance of 20 pF ± 2 pF- Meets the requirements of ANSI/ESD STM3.1 and ANSI/ESD SP3.3- Designed to perform audits on overhead ionizers and room ionization systems- Flexible to also evaluate and balance bench top ionizers- Completely collapsible for compact storage- Designed to be used with the PFM-711A and PFM-711B
-
product
Autoanalysis System Set
PGA-710B
The PGA-710B is a unique electrostatic data analysis device for use with Prostat's PFK-100B Field Meter and Charge Plate Monitor kit. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions.
-
product
Periodic Verification System for Measuring Static Charges and Verifying Ionizer Performance
STME-PVS
Statclean Technology (S) Pte Ltd
This meter is designed to measure static charges and to verify ionizer performance. It consist of three components- an Electrostatic Fieldmeter, a Detachable Plate and a Charger.
-
product
Periodic Verification System
Model 775 PVS
The Simco-Ion Periodic Verification System Model 775PVS is a hand-held alternative to a charged plate monitor. It consists of three components-a fieldmeter, a detachable plate, and a charger for measuring static charge and verifying ionizer performance. Used alone, the fieldmeter measures electrostatic fields on any surface.
-
product
Walking Test System Kit
PGA-710
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
product
3-Component Quartz Force Rings
260 Series
Three-component quartz force ring sensors are capable of simultaneously measuring dynamic force in three orthogonal directions (X, Y, and Z). They contain three sets of quartz plates that are stacked in a preloaded arrangement. Each set responds to the vector component of an applied force acting along its sensitive axis. 3-component ring force sensors must be statically preloaded for optimum performance. Preloading provides the sensing elements with the compressive loading required to allow the proper transmission of shear forces. Versions are available with ranges up to 10k lb (45k N) in the z-axis (perpendicular to the top surface), and up to 4000 lb (18k N) in the x-and y (shear) axes. Both ICP® and charge output styles are available.