Filter Results By:
Products
Applications
Manufacturers
-
product
PXI FPGA & Measurement Accelerator
Keysight PXI FPGA & measurement accelerator provide digital-pre-distortion (DPD) and envelope tracking (ET) measurements that are embedded in high performance FPGA processing cards.
-
product
PXIe Measurement Accelerator
M9451A
The M9451A PXIe Measurement Accelerator combined with Option DPD Digital Pre-Distortion & Envelope Tracking Gateware shows what is possible when you combine state of the art FPGA's with Keysight's trusted measurement expertise and PXIe's high speed data handling. As part of Keysight's RF PA/FEM Characterization & Test, Reference Solution, this combination provides unprecedented performance for demanding envelope tracking and digital pre-distortion measurements required for testing modern power amplifiers (PAs) and front-end modules (FEMs). Hardware acceleration provides better than 20x speed improvement over Keysight's previous host-based Reference Solution, with closed/open loop digital pre-distortion (DPD) and envelope tracking (ET) measurements taking just tens of milliseconds and overall measurement times less than 70 ms.
-
product
Cylinder type, Near field Antenna Measurement System
anm02
As it combines the vertical direction of the probe antenna with the turn of the object antenna, and performs the near field measurement in the shape of a cylinder. The result will be converted to far field. Feature The pattern behind the antenna can be measured by a cylinder scanning. Fast measurement.For example ) Vertical direction 256 point and Rotatory direction 180 point : 30 minutes.
-
product
EMC Accessories
Complete your EMC test setup with the essential accessories to compliment the test equipment. Whether it is a LISN (or V-Network) to counteract interference from external power sources on conducted emissions from the device under test, probes to locate the near field sources of radiated emissions, receive and transmit antennas, or tripods for holding antennas in place, the Rohde & Schwarz catalog of EMC accessories provides the additional items you need for EMI and EMS measurements, guaranteed 100% suitable for use with Rohde & Schwarz EMC test equipment.
-
product
EMF Measurements Antennas
An isotropic antenna that allows to carry out radiated emission and environment exposure measurement (elettrosmog) to the radio frequencies in proximity of radio and television stations and repeaters for mobile telephone.
-
product
EMF Measurements/EM Measurements/Electromagnetic Radiation
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.
-
product
Handheld Vector Network
ZNH
R&S®ZNH is a full two-port handheld vector network analyzer that offers one-port cable and antenna measurement and full two-port S-parameter measurements. The touch based interface is simple to operate and a configuration overview menu makes measurement preparation more efficient. The R&S®ZNH may have a small form factor but it is complete in every detail and delivers high performance and all the key functionalities.
-
product
Heavy-Duty Antenna Measurement System
0 to 360 degree AZ+/- 90 degree EL Dual-axis high-resolution antenna positionerTwo Precision SMA measurement cablesIncludes DAMS Antenna Measurement Studio ProComplete package includes all accessories
-
product
HF Analyzer
HFA-3
PC connection precision measurements using the latest microprocessor technology Long-term recording simplest operation Measurement display in W / m or mV / m Frequency filter for major mobile phone networks and other services (GSM900, GSM1800, UMTS, DECT, WiFi, Bluetooth) precision EMC -LogPer antenna sound latest circuit technology best quality supported by universities confirmed by reports
-
product
Horn Antenna
TDK HRN-0118
The TDK HRN-0118 broadband horn antenna (1 GHz to 18 GHz) is designed specifically for radiated emissions and immunity measurements in EMC test environments. The HRN-0118 horn antenna provides optimal performance over the frequency range of 1 GHz to 18 GHz.
-
product
Log Periodic Antennas
Log Periodic antennas allow quick sweep measurements without a band break. This feature makes it convenient to use the Log Periodic antenna with a automated emissions or immunity measurement system. The size of the antenna also allows it to be used in a small area like a shield room.
-
product
Measuring Small Antennas
If you have a small PCB with a small antenna you can't use a thick cable and a large connector. Not only is this impractical (how to connect the connector?) but the metal bulk will also affect the antenna and grounding properties of your PCB. The measurement will be useless. MegiQ promotes the use of the small and popular UFL connector and its associated cables. The UFL socket fits on almost any PCB and it can be improvised on a board without a UFL footprint.
-
product
Multi-function GPS/GLONASS Research Receiver
R100
The Multi-function GPS/GLONASS Research Receiver sets the standard in precision and versatility for GPS/GLONASS research. It provides highly accurate navigation, ionospheric measurement, time transfer, satellite monitoring and differential reference station capabilities. When combined with the temperature stabilized antenna it eliminates delay variations due to outside temperature, affording even greater accuracy.
-
product
Near Field Probes
A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.
-
product
Omni-Directional Antenna
EM-6104-1 | 20 MHz-18 GHz
The EM-6104-1 is an omni-directional, dual band, hybrid antenna covering 20 MHz-18 GHz. The antenna features wide frequency coverage making it an excellent choice for a variety of applications such as general purpose measurements as well as wideband security applications. This lightweight antenna is ideal for deployable applications that require wideband coverage in a very small footprint. The antenna’s elements collapse for convenient storage and transport. The antenna is configured to mount on a standard ¼-20 tripod stud. The EM-6104-1 Omni-Directional antenna is supplied with an EM-6089 Battery Pack.
-
product
OTA Power Measurement Solution
NRPM
The R&S®NRPM is a fully calibrated and individual scalable OTA power measurement solution for benchtop application or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz it is perfect for Over-the-Air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of the transmit antenna output power.
-
product
Power Quality Analyzer
PQM-703
Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.
-
product
Radiated Emission
High accuracy CISPR 16-1-1 EMI receivers and high precision calibrated antennas for radiated emission measurements.
-
product
Signal Level Meters
The SignalScout (SS40) provides fast and accurate measurement of signal strength when tuning an antenna for a local TV channel.
-
product
SparkFun Pulsed Radar Breakout
A111
Does your project require high-precision, cutting-edge distance measurement? Or maybe speed, motion, or gesture-sensing? We're not talking about simple ultrasonic or even infrared here, but 60GHz radar! Well say hello to the SparkFun A111 Pulsed Radar Breakout! The A111 is a single-chip solution for pulsed coherent radar (PCR) and comes complete with an integrated antenna and an SPI interface capable of clock speeds of up to 50MHz. Though the A111's primary use case is distance-sensing, it also supports applications in gesture, motion, material, and speed-detection at distances of up to two meters.
-
product
Test Services
Microwave Instrumentation Technologies, LLC
AMETEK NSI-MI's world-class test facilities uses industry-leading equipment and instruments to support your specific needs. A2LA-accredited measurement facilities, combined with our expert staff of engineers, can tackle any unique test and calibration requirements with precision and accuracy. Our equipment is calibrated with NIST traceability providing you with the assurance that we can accurately and consistently characterize your antennas, radomes and other devices.
-
product
Test Services
NSI-MI Technologies offers its world class test facilities for use to industry, government and educational clients. NSI-MI’s industry leading equipment and instruments are available to support your specific requirements. Our measurement facilities, combined with our expert staff of engineers can tackle any unique test needs with precision and accuracy. Our facilities are A2LA accredited and our equipment is calibrated with NIST traceability providing you with the assurance that we can accurately and consistently characterize your antennas, radomes and other devices.
-
product
Fiber optic active antennas / field probes
EFS-105
The EFS-105 is the first in a family of fiber-optic active antennas & E-field probes. The field distortion caused by the probe head is nearly zero due to the exceptionally small probe head and the all-optical signal transmission and power supply. This gives an invaluable advantage for near field measurements and measurements close to metallic parts.
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
GPS Speedometer/GPS Vector Speedometer
LC-8120/LC-8220
The LC-8120/8220 is the GPS-based speedometers which measure speed and distance of moving objects with high accuracy. Support for GLONASS satellite which is not supported in the conventional model (LC-8100A/8200A) to ensure stable measurement. Antenna for LC-8220 (LC-0721) is smaller and lighter than the conventional antenna for LC-8200A (LC-0086) and it enables easy operation. The new antenna (LC-0721) is able to attach to the conventional unit of LC-8200(A) for measurement. The linearity of acceleration and angular speed are improved by using the standard IMU (inertial measurement unit) together with the optional high accuracy IMU. Also, by adding the high response IMU analog output function (option), the analog output frequency of the IMU data can be increased from 100 Hz to 500 Hz. A wide range of optional functions such as white-line detecting function (LC-0856), jerk measurement function (LC-0871) and average deceleration speed calculation (function in the LC-0831) are available for various automotive tests.
-
product
Medium-size Reverberation Chamber
E-Series
The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.
-
product
Active Monopole Antenna
AM-741
The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the rod were located below the ground, and the ground removed. Since the stainless steel plate does not have enough surface area to mirror the entire 41 inch rod, it is bonded to the surrounding ground plane during use. The AM-741 is battery powered to prevent measurement errors that maybe caused by external power cables. The ANSI equivalent capacitance substitution (ECSM) method is the recommended method for calibrating AM-741 monopole antenna. The individual calibration data will be included with each antenna.
-
product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
product
Antenna, Log Periodic
EM-6952-1 | 1 GHz – 2 GHz
The Electro-Metrics EM-6952-1 Log Periodic Antenna operates over the 1 to 2 GHz frequency range. The EM-6952-1 is capable of operating either as a transmitting or as a receiving antenna over the frequency range of 1 to 2 GHz. Its linearly polarized designed permits separate measurement of horizontal and vertical electric field components over its established range. Enclosed in a weather resistant radome, this antenna is suitable for indoor or outdoor usage.
-
product
Monopole Antennas
Our Monopole Antennas provide superior performance in electric field measurements. The Active Monopole Antenna can drive any receiver with 50W input impedance and will perform FCC, MIL-STD and TEMPEST tests. The passive rod is used for transmitting, to perform shielding effectiveness and immunity testing.