Line Replaceable Unit
unit of a complex engineered system, designed for quick replacement.
See Also: LRU
- Pickering Interfaces Inc.
product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Air Data Computer (ADC) Tester
MS 1122
The ADC tester is used in 2nd line maintenance is to check the functionality of ADC. This unit is a rugged customized hardware based on full functionality test of ADC. The Air Data Computer (ADC) Tester is a fully automated GO/NOGO tester with full functional testing in 2nd line maintenance. This tester is to test ADC at unit level and identify faulty Shop Replaceable Unit (SRU). This tester is also used to carry out PI checks on ADC before clear them for installation on aircraft. ADC Interface ...show more -
product
Pulse AC Method Area Ionizers
ER-X Series
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy...show more -
product
Avionics Suite Tester
Based on order from the Navy, Data Patterns developed the complete Automated Test Equipment required for validating all the Line Replaceable Units (LRUs) utilized in the Seaking Helicopter. The upgrade was carried out at multiple Naval bases in India.
-
product
Processor and NVIDIA Quadro GPU
MAGIC1A
The MAGIC1A is a rugged line replaceable unit (LRU) suitable for high-performance computing in the harshest of environments. The combination of Intel and NVIDIA processors in a low SWaP-C3 package ensure it can be used across a wide range of commercial and military applications, including displays, situational awareness, data/radar processing, video processing, classification, and artificial intelligence (AI).
-
product
Depot Repair & Redesign
ARC has worked with the DoD/military agencies and the FAA to help service and repair critical products in the national air system and various line replaceable units (LRUs) that may contain multiple circuit cards. With a skilled team of engineers and service technicians that can troubleshoot, reverse engineer, and help in finding components for damaged and obsolete parts, ARC is the right depot partner.
-
product
GPU
The MAGIC1A is a rugged line replaceable unit (LRU) suitable for high-performance computing in the harshest of environments. The combination of Intel and NVIDIA processors in a low SWaP-C3 package ensure it can be used across a wide range of commercial and military applications, including displays, situational awareness, data/radar processing, video processing, classification, and artificial intelligence (AI).
-
product
Instrumentation Amplifiers
HIGH-POWER RADIO FREQUENCY (RF) AND MICROWAVE AMPLIFIERS, TWTA AND SOLID STATE
Communications & Power Industries
electromagnetic compatibility (EMC) high-intensity radiated field (HIRF) testing, military testing, electronic warfare simulation and scientific applications are based on the same switched-mode power supply technology as its rugged amplifiers. As a result, these instrumentation amplifiers have all the same performance and reliability advantages as the rugged product line, but have been neatly re-packaged into compact, lightweight and affordable rack-mountable units more suitable for less demandi...show more -
product
S500 Test Solution
The S500 Bench Test Equipment (BTE) is customized to test the Line Replaceable Unit (LRU) to determine the faulty Lowest Level Replaceable Unit (LLRU). Once a faulty LLRU is discovered, a separate application program specifically designed for the LLRU is executed to further isolate the fault.
-
product
AIS Air Data Test System
F-16
The primary function of the Air Data Test System (ADTS) is to perform testing and fault isolation of pneumatic-type Units Under Test (UUTs). To test a UUT, the operator connects the associated Line Replaceable Unit (LRU) Integrated Test Adapter (ITA) to the rackmount Avionics Intermediate Shop (AIS) test station. The operator connects the ADTS to the IAIS via an RS-232 Interface and then finally, connects the UUT to the ADTS using the supplied cables and hoses.
-
product
Air Data Calibration Test System (ADCTS)
ADCTS-1000 Series
TestVonics Air Data Calibration Test System (ADCTS) is high precision advanced Secondary Air Data Controller-Monitor system. The ADCTS-1000 Series is a self-contained maneuverable rack mounted air data management system. The ADCTS is used in calibration labs, avionics engineering and avionics/instrument shops. The system is designed to perform both manual or automated test and calibration routines for a variety of air data test equipment (ie. test sets, air data computers, altimeters, airspeed indicators and line replaceable units). The ADCTS can be configured for use in both commercial and military environments.
-
product
PXIe-4144, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit
782432-01
PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit - The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
product
DFB Laser Source Module
LaserPXIe 1200 Series
The LaserPXIe 1200 Series is a highly customizable DFB laser source available in a wide range of wavelengths and powers.
-
product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI Source Measurement Unit
PX773x
The PX773x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technolog...show more -
product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-194A-002-HI
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
product
6x 3U OpenVPX MOSA Remote Interface Unit
SIU36-RIUVARM-01
SIU36-RIUVARM-01 is a Modular Open Systems Approach (MOSA) Remote Interface Unit (RIU) to manage, monitor and control connected I/O, communications, measurement and simulation interfaces through Ethernet commands from a main mission processors. Extremely low power with 2 x 10/100/1000Base-T Ethernet.
-
product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and ...show more -
product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-302
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
4x 3U OpenVPX MOSA Remote Interface Unit
SIU34-RIUVARM-01
SIU34-RIUVARM-01 is a Modular Open Systems Approach (MOSA) Remote Interface Unit (RUI) to manage, monitor and control connected I/O, communications, measurement and simulation interfaces through Ethernet commands from a main mission processors. Extremely low power with 2 x 10/100/1000Base-T Ethernet.
-
product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology,...show more -
product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test