Filter Results By:
Products
Applications
Manufacturers
-
product
Differential Scanning Calorimetry
Nano DSC
The Nano DSC differential scanning calorimeter is designed to characterize the molecular stability of dilute in-solution biomolecules. The Nano DSC obtains data using less sample than competitive designs. Solid-state thermoelectric elements are used to precisely control temperature and a built-in precision linear actuator maintains constant or controlled variable pressure in the cell. Automated, unattended continuous operation with increased sample throughput is achieved with the optional Nano DSC Autosampler.
-
product
Laboratory Incubators
DB & TE Series
These laboratory incubators have a wider range of temperatures. Also, these might be purchased if the role of the chamber might switch in future use – for example from cooler to above ambient temperatures. We have two types of heated and cooled incubators. The DB series incubators use compressor technology and have temperature ranges of 4°C-60°C. The TE series incubators use thermoelectric technology and have temperature ranges of 20°C-60°C.
-
product
Lasers FP/DFB-LDs For OTDR
C is a 1 650 nm Multiple Quantum Well (MQW) structured Distributed Feed-Back (DFB) pulsed laser diode DIP module with single mode fiber and internal thermoelectric cooler. It is designed for light sources of Optical Time Domain Reflectometer (OTDR).
-
product
Robust Stability Meter
MR 1012 S
Owing to its high measuring rate, its compact and robust design, ist accuracy and long-term stability, the digital ohmmeter MR1012S can be used in applications with high requirements concerning the measuring stability and reliability. This is guaranteed by the integrating measuring method according to the quotient principle, the compensation of all thermoelectric forces and other offset voltages, as well as the suppression of interference voltages in the measuring and data lines induced e.g. by HF.
-
product
Sample Conditioner
PCA-400
Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.
-
product
sCMOS Camera
Quantalux
Thorlabs' Quantalux™ Scientific CMOS (sCMOS) Camera offers extremely low read noise and high sensitivity for demanding imaging applications. The compact housing has been engineered to provide passive thermal management for the sensor, reducing dark current without the need for a cooling fan or thermoelectric cooler. These features makes the Quantalux camera ideally suited for low-light imaging applications such as fluorescence microscopy.
-
product
Thermal Transport
The thermal transport probe measures thermal conductivity and thermoelectric power (defined by the Seeback Coefficient). Electrical and thermal contacts are made to opposite ends of the sample allowing for customisation to suit the sample requirements of the user.
-
product
Thermocouples
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
product
Thermoelectric Cooler Controller
Analog Devices Thermoelectric Cooler Controllers work with cooler based photonics, offer the smallest size, the best efficiency and the most robust solutions. It has a linear power stage with the linear driver output and a pulse width modulation power stage with the SW output. Depending on the part number, it offers digital PID control or analog PID control or both. Our TEC controllers support a variety of MSA based optical modules such as SFP, SFP+,QSFP+, CFP/CFP-2/CFP-4 and QSFP28.
-
product
Ultra-Low-Noise CCD and X-Ray Cameras
SOPHIA® Family
Teledyne Princeton Instruments
SOPHIA® has ultra-low-noise electronics, with high sensitivity (>95% QE), speed and flexibility with multi-port readout capabilities up to 16 MHz and high frame rates. ArcTec™ technology allows for thermoelectric cooling without chillers or cryo-coolers.
-
product
X-Ray Cameras for Soft X-Ray, VUV, and EUV Applications
SOPHIA® XO
Teledyne Princeton Instruments
SOPHIA® XO offers high-sensitivity (>95% QE) and high-speed for the widest range of VUV and x-ray detection, with thermoelectric cooling up to -90℃ and high frame rates. With a rotatable, industry-standard CF flange and high-vacuum seal design the software-selectable gains and readout speeds make this camera well suited for UHV applications.
-
product
Environmental Rooms
Darwin Chambers Company designs, manufactures, installs, and services custom chambers of all types and sizes, for a wide array of applications, including: GMP Shelf-Life Testing and Storage, Dry/Moist and Cold Storage for Seed and Agricultural Products, Nutritional Supplements, General Materials Testing, Mold and Fungal Incubation, Photography Storage, Concrete Curing, Roll-In Bottle Incubation Chambers and Compliant Vivariums (NIH, ALAAC, OLAW, USDA, etc.), more. We have pioneered a number of innovative, resource-saving technologies, from thermoelectric and liquid-circuited cooling systems to ultrasonic humidification.
-
product
Contact Temperature Sensors
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
product
Hygrometer, 3 State Thermoelectric Cooler
CR - 5 Hygrometer
Buck Research Instruments, LLC
The CR-5 is a chilled mirror hygrometer that uses a 3-stage thermoelectric cooler (TEC) to enable frost point measurements of as low as 60 C, under favorable ambient conditions. It is configured as a transmitter module with an external sensor connected by cable up to 9 feet in length.
-
product
Hygrometer with 3 Stage Thermoelectric Cooler
CR - 4
Buck Research Instruments, LLC
The CR-4 is a chilled mirror hygrometer that uses a 3-stage thermoelectric cooler (TEC) to enable frost point measurements of as low as - 65C, under favorable ambient conditions. Depending upon ambient temperature, it can measure dew points as high as 60C.
-
product
Aircraft Hygrometer
1011C
Buck Research Instruments, LLC
The 1011C Aircraft Hygrometer is a complete chilled mirror optical dew point system for monitoring atmospheric dew and frost points. It provides three stages of thermoelectric cooling, and can reach frost points as low as -60 to -90 C, depending on mounting configuration and operating conditions. No auxiliary coolants are required.
-
product
Detector & Controller
LM-Pbs TEC1
Lead-Sulfide Detector (Range: 1 - 2.4 micron) Detector element is 5mm x 5mm. Has a 2 stage Thermoelectric Cooler which increases the gain by 3x without an increase in noise. This is a recommended upgrade when using a monochromater with a LMC-20.
-
product
Solar Total Pyranometers
SK08 & SK08-E
The Middleton SK08 is an affordable pyranometer for the measurement of global solar irradiance on a plane surface. It meets the international accepted specifications for a good quality pyranometer. The SK08 incorporates a passive thermoelectric sensor. The SK08-E version has an inbuilt signal amplifier.