Filter Results By:
Products
Applications
Manufacturers
-
product
Click Analysers
A click is defined as a disturbance exceeding the limit of continuous noise for not longer than 200ms, separated from a subsequent or preceding disturbance by at least 200ms.
-
product
Electrical Network Analyzer
Portable disturbance recorder APR64P with its accessories Allows monitoring of 8 or 16 analog channels and 3 to 32 digital channels.
-
product
EMI Test Receiver
ESW
With its outstanding RF characteristics, high dynamic range and measurement accuracy, the R&S®ESW is the best choice for fast and reliable certification measurements. It meets the most stringent requirements in line with CISPR, EN, MIL‑STD-461, DO‑160 and FCC. The R&S®ESW captures and weights disturbance spectra very fast with its FFT based time domain scan. The real-time spectrum analysis with spectrogram function permits detailed analysis of even the shortest disturbance signals. MultiView mode delivers a simultaneous display of results from multiple operating modes for best instrument usability.
-
product
Fast Digital Integrator
FDI2056
The Fast Digital Integrator FDI2056 is the world's fastest and most sensitive voltage integrator. Simply plug in a sense coil and measure fast, low-level magnetic field disturbances such as eddy currents in a switched magnet.Equipped with a high-speed Analog-to-Digital Converter (ADC), high-resolution clock, and highly optimized digital integrator, the FDI2056 boasts a maximum of 500 000 partial integrals per second and provides resolutions down to 10-14 Vs with an accuracy of 10 ppm. Magnetometer Fluxmeter
-
product
Geological Faults
A fault (also rupture, crack, displacement or disturbance in the narrower sense) is a tectonic tear or fracture in the rock, which offsets two rock areas or crust parts over distances from the centimeter range to a few tens to hundreds of kilometers.
-
product
HEAD acoustics Radio Analyzer Tool
TUNE
The HEAD acoustics Radio Analyzer Tool TUNE allows a reproducible analytical evaluation of the impact of analog radio broadcast disturbances on perceived audio quality based on auditory test results.
-
product
Load Shedding System
An advanced smart load preservation solution must dynamically determine the optimal system response to a variety of system changes and disturbances. Utilizing model-driven foundation with embedded predictive analytics, and optimization algorithms, ETAP's adaptive Intelligent Load Shedding (ILS) solution makes Faster than Real-Time decisions.
-
product
Magnetometer
MFM-1
For the measurement of magnetic equilibria such as the earth's magnetic field and for the determination of anomalies and biologically active location factors. The external measuring probe is connected to the measuring device by a probe cable, as a result of which an exact probe guidance is possible in places which are difficult to access. The disturbance source can be localized by the directional characteristic of the measuring probe.
-
product
Measurement Technology for Teaching and Training
Is particulary suitable for training and further education. With the disturbance emission model, a variety of different experiments which improves one`s understanding of electromagnetic processes in modern electronic engineering are possible. The coupling mechanisms of disturbance emissions are visualized from their sources to the antenna. The impacts of EMC measures are then easier to understand. At VM 251 the electromagnetic d
-
product
MP CI set
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)
-
product
Power Quality Software
Save Time and Improve Accuracy When Troubleshooting AnswerModules® are proprietary algorithms that convert raw power quality event data into precise answers to determine the source and cause of the disturbance. Read More
-
product
Programmable AC and DC Power Source
AFX Series
The AFX Series is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 6 kVA to 90 kVA with available configurations to 150kVA. Using a modern user interface for ease of use, the AFX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications.
-
product
Programmable Wide Frequency AC Power
PWF series
The PWF series is a family of programmable AC power source with wide range of adjustable frequency, developed for aerospace or military’s 400Hz and 800Hz test applications, such as lab use, compliance test, and quality assurance. The PWF series consists of L series and M series, which have different output frequency range. L series provides 45~500Hz and 0~300V output, and M series provides 300~800Hz and 0-150V output. Users can select communication interfaces of RS-485, RS-232, and optional GPIB. The PWF series also have programming sequence functions of STEP and GRADUAL modes, three phase independent control, phase angle control, and disturbance function.
-
product
Pulsed Withstand Voltage Safety Test
Suzhou 3ctest Electronic Co.,Ltd.
designed to test the induced and conducted disturbance on the telecom lines generated by power line and electrical railway. It meets the requirements of YD/T 993-2006(The technical requirements and test methods of over-voltage and over-current resistibility for telecommunication terminal equipment),
-
product
Pulsed Withstand Voltage Safety Test
Suzhou 3ctest Electronic Co.,Ltd.
Designed to test the induced and conducted disturbance on the telecom lines generated by power line and electrical railway. It meets the requirements of YD/T 993-2006(The technical requirements and test methods of over-voltage and over-current resistibility for telecommunication terminal equipment), ITU-T K21 and ITU-T K44.
-
product
Scintillation Counter
G-Explorer
Highly sensitive, reliable and innovative radiation measurement technology. Explore and discover radioactive radiation in the environment with reliable accuracy! Use the graphical data preparation to find underground mineral deposits, such as water, caves and geological disturbances, even on large areas.
-
product
Shear Stress Sensors
DirectShear™
Micromachined floating element shear stress sensor that enables time-resolved, one-dimensional, direct shear stress measurements. Direct measurement of shear stress — no heat transfer calibration. Non-intrusive — minimal flow disturbance. Simultaneous mean and fluctuating shear stress measurements. High resolution, dynamic range and bandwidth. Highly accurate, quantitative measurements.
-
product
Single Phase Powerline Monitors
a Voltage disturbance detector and recorder. This device is designed to be plugged into a 120V or 240V AC line and will monitor this line for voltage disturbances and temperature or Humidity variations.
-
product
Telurometer
AMRU-10
AMRU-10 is a simple meter that allows to perform measurements by the technical method, as well as the measurement of the resistance of the grounding by the bipolar method. The device is characterized by its ease of operation, high resistance to disturbances and high accuracy.
-
product
Three-axis Fluxgate Magnetometer
TFM1186
The Three-axis Fluxgate Magnetometer TFM1186 is a member of Metrolab's THM1176 family of 3-axis handheld magnetometers. It is a lightweight, low-power, go-anywhere fluxgate magnetometer. Outstanding noise characteristics make fluxgate magnetometers the instrument of choice for measuring minute disturbances in the local magnetic field, for example due to an iron mass or AC power-line noise. The TFM1186 has a range of ±100 µT and a resolution of 4 nT. The TFM1186 simultaneously measures all three axes of the magnetic field, so you get a true field strength reading no matter how you hold the probe. The entire instrument has been reduced to a cable with a few fat spots, which can plug directly into your PC or into a battery-powered handheld computer. 3-axis Teslameter Gaussmeter
-
product
Three Phase Voltage Disturbance Recorder
PQR 2020
The PQR 2020 is a Three Phase Voltage disturbance detector and recorder. This device is designed to be connected to a single phase 120V or 240V AC line or a Three Phase 208/240/480 Volt AC line and will monitor these lines for voltage disturbances.
-
product
Voltage Probe
VOL-PBE
• EMI Receiver equipped with voltage probe can test disturbance voltage from load terminals or control terminals
-
product
Absorbing Clamps
The absorbing clamps also known as ferrite clamps are used for measuring disturbance power on power input lines as well as other auxiliary I/O lines.
-
product
RFI Power Emission
AFJ receivers and accessories for the disturbance power using the absorbing clamp measurement, are conforming to CISPR 16-1-1 and CISPR 14-1.
-
product
Burst Detectors
The Burst detector monitors interference threshold exceedances at cable-and line bundles. It selectively detects conducted disturbances, which would influence the monitored device.
-
product
AC Power Source
AC power source 61500 series sets up the new standard for high performance AC power source. It equips with all powerful features such as power line disturbance (PLD) simulation, programmable output impedance, comprehensive measurement functions, wave-shape synthesis and regulation test software.
-
product
AC Source
AFV
The AFV Series is a broad line of programmable three phase AC power sources. With Power levels ranging from 15kVA up to 2MVA, the series powerful FPGA+ARM based controller offers precise voltage and frequency conversion with power disturbance generation capability. Power is supplied by state-of-the-art IBGT pulse-width-modulated power amplifiers resulting in highly efficient power conversion, compact design and maximized performance.
-
product
Active probe 50 Ohm Differential SMB
80609010
The differential active probe helps to carry weak HF signals far away with the minimum disturbance of the original source. The module accepts discrete wiring or direct spring loaded test probe solder. In any case, the input signal wires might be as short as possible.
-
product
Active Probe 50Ohm Single Ended SMB
80609000
The single ended active probe helps to carry weak HF signals far away with the minimum disturbance of the original source. The module accepts discrete wiring or direct spring loaded test probe solder. In any case, the input signal wires might be as short as possible.
-
product
Active Probe 75Ohm Single Ended SMB
80609007
The single ended active probe helps to carry weak HF signals far away with the minimum disturbance of the original source. The module accepts discrete wiring or direct spring loaded test probe solder. In any case, the input signal wires might be as short as possible.