-
product
Bench Power Supply, Adjustable, 2 Output, 0 V, 32 V, 0 A, 3 A
72-8690A
The 72-8690A from Tenma is a dual channel general DC power supply suitable for laboratory use. The dual channel (CH1 and CH2) can work in CV or CC mode and these two modes convert automatically according to the load. The CH1 and CH2 have auto tracking function. In this condition, the output of CH2 tracks the output of CH1. This function is usually used when adjustable symmetrical and double polarity power is required. Both CH1 and CH2 display the output voltage or current with a 6 digit LED meter. The main outputs can be connected in parallel or in series. This product comes with 2 years warranty.
-
product
Ferroelectric Test System
RT66B
Radiant's Rt66B offers amazing performance at an affordable price. The Rt66B is a perfect entry level system for measuring Ferroelectrics. This system does include Radiant's famous Vision Data Management System which offers all the standard measurements of ferroelectrics including Hysteresis, Fatigue, Waveform, C/V, I/V, PUND and much more.
-
product
Software
Quasi-Static Measurements
Materials Development Corporation
The Quasi-static measurement ompares a high frequency capacitance-voltage plot to a C-V plot measured near zero Hertz (quasi-static). By analyzing the difference in the depletion region of the curves, the interface trap density (Dit) can be determined in the sample under test.
-
product
Digital CC and CV DC Power Supply
DC3005
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and can output costant current or constant voltage. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer’s request.
-
product
Semiconductor Switching Systems
Keithley 700 Series
The high speeds and low currents of semiconductor devices demand high quality, high performance switching of I-V and C-V signals. We offer switching solutions for both semiconductor R&D and production test applications with mainframes that can support up to 2,880 channels and a family of matrix cards designed specifically for semiconductor applications.
-
product
High Power DC Electronic Load
34000A Series(5KW~40KW)
34000A Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
product
Programable DC Power Supply
ADG-L Series
14 models and three different output power, 4kW, 8 kW and 12 kW. Utilizing PWM technology, ADG-L delivers stable output and precise measurement. With CV, CC and CP mode, ADG-L series is ideal for Photovoltaic, Electric Vehicle, battery, fuse/capacitor and third party laboratory testing.
-
product
160W Programming Laboratory Grade Power Supply
Source effect: *CV≤0.01%+3mV(mA) *Load effect: CV≤0.01%+3mV(I≤3A) CC≤0.2%+3mA(I≤3A), CV≤0.02%+5mV(I>3A) CC≤0.2%+5mA(I>3A) * Ripple and noise: CV≤1.0mVrms(I≤3A) CC≤3mArms(I≤3A), CV≤2.0mVrms(I>3A) CC≤6mArms(I>3A) * Protection Type: Overcurrent Protection (OCP) Overvoltage Protection (OVP) * Display accuracy: Voltage indication accuracy: ± (0.5% + 2 words)
-
product
DC Electronic Load
3310G Series(800W)
Has its own control and display panel, CC / CR / CV / CP / Dynamic modes, with 150 sets Store / Recall memory which provides load set-up more efficiently, also can be controlled via RS232、Ethernet、USB and GPIB interface
-
product
GPIB Serial Interface
Model 4894B
* Provides RS-232C single-ended and RS-422/RS-485 differential serial signals. * Expanded baud rate range from 50 to 115,200 baud.* 256 Kbyte RAM buffer for spooling data.* Over 600 Kbyte/second GPIB data transfer rate.*Transparent data transfer.* Programmable replacement for the NI CV interfaces.* 1 U high rack mount kit mounts one or two 4894Bs* Includes US 115 VAC Power Adapter, Manual and Support CD.
-
product
Cryogenic Probe Station
CPX-VF
The Lake Shore CPX-VF probe station enhances the standard probe station capabilities with the addition of a ±2.5 T vertical field superconducting magnet. It can do all the standard C-V, I-V, microwave, and electro-optical probing of the CPX, plus out-of-plane vertical field superconducting magnetic measurements. Researchers can use it to perform Hall effect measurements and test magneto-transport parameters. The CPX-VF is one of Lake Shore’s premium probe stations for combining microwave measurements with magnetic field.
-
product
DC Electronic Load
3110 Series(250W~700W)
Each 3110 Series stand-alone load has its own control and display panel, CC / CR / CV / CP/ Dynamic modes, also can be controlled intranet via RS232 and USB interface.
-
product
Electronic Loads
PeakTech Prüf- und Messtechnik GmbH
Can be used for important test procedures in quality assurance as well as e.g. testing of power supplies and control units, batteries, fuel and solar cells. For precise load control for various purposes, this device offers load control according to constant voltage (CV), constant current (CC), constant load resistance (CR) or constant power (CP) with a highly precise resolution of 1mW, 1mV, 1mΩ and 1mA. The device also offers additional test modes, e.g. the battery test or the dynamic test. The PC interface and software offer the option of implementing freely programmable test sequences with data evaluation.
-
product
High Power DC Electronic Load
34000C Series(6KW~24KW)
34000C Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.
-
product
LED Load Simulator
63110A/ 63113A/63115A
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is ...show more -
product
QS603 60V/3A Power Supply
*16 hours at full load*Low ripple and noise*Automatic switching CV / CC*Aluminum heat sink*Displays 3 or 4 digit depending on the model
-
product
IT Battery Test System
Shenzhen Sinexcel RE Equipment CO., Ltd
IT battery test system support for multiple charging mode (such as CC, CV, CP, pulse, etc.) and discharge mode, to ensure that the battery performance and safety in the practical application. IT battery test system is designed to be modular, easy to maintain, and with anti-reverse connection, data loss and other protection functions
-
product
Regenerative Battery Pack Test System
17020E
Charge/discharge modes (CC, CV, CP)Power Range: 10kW / 20kW per channelVoltage Range: 60V/ 100VCurrent Range: 100A/200A/300A/400A/ 500A/600A/700A/800A per channelRegenerative battery energy discharge, efficiency 85%Channels paralleled for higher currentsDriving cycle simulationFast current conversion without current interruptHigh precision measurementSmooth current without over shootTest data analysis functionData recovery protection (after power failure)Independent protection of multi-channel
-
product
High Power DC Electronic Load
3350G Series(4KW~6KW)
Each 3350G Series module has its own control and display panel, CC / CR / CV / CP /Dynamic modes, also can be controlled via RS232、Ethernet、USB and GPIB interface.
-
product
High Power DC Electronic Load(1250V)
36300E Series(50KW/60KW)
36300E Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
product
Machine Vision Computer with Built in I/O
Neousys Nuvis
Nuvis-5306RT , Nuvis-534RT, Nuvis-7306RT contain interfaces for connecting to all necessary devices: LED lighting controller, camera trigger, encoder input, PWM output and digital I / O lines.- Intel® 7th Gen Core ™ i7 / i5 65W / 35W, up to 32GB DDR4- Built-in I / O- 4-CH CC / CV backlight controller- 4-CH trigger camera- 1-CH quadrature encoder input- 8-CH isolated DI and 8-CH isolated DO- Built-in camera interfaces- 4-CH IEEE 802.3at Gigabit PoE + ports- 4-CH USB 3.1 Gen1 ports- NVIDIA 75W GPU Support
-
product
Software
MOS Doping Profile Analysis
Materials Development Corporation
MDC uses the comprehensive Ziegler algorithm toconvert pulsed MOS C-V data to a doping profile. The doping profile is accurate from the oxide semiconductor interface to the maximum depletion depth and is therefore useful for low dose ion implant monitoring. Peak doping, range, and total active dose are computed. The technique is sensitive enough to resolve changes in the substrate doping profile due to redistribution during oxidation.
-
product
Mini Digital Clamp Tester (CE)
M-140HC
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy!:Measurale Load Current at high voltage CV/CVT cables with grounding lines for shield phase.*Epoch-Making!:Can measure phase current of CVT cable just by putting CT head on to the conductors as well as CV cable just by clamping CT to the conductors in a lump.*Low Cost!:Can measure line/leakage current in the same manner as ordinary clamp meters.
-
product
LED Driver Aging Rack
LEDRACK-100W192P
• Application range: LED driver and multi channel driver power aging. It has equipped with computer operation and monitor system. The working condition can be set by the computer, and the computer will record real time data to do statistical analysis. • The parameters of load can be set freely on the software, to monitor the real time voltage, current, and power etc • Load mode: CC, CV, CR, CP, and LED • Aging Control System includes: ON/OFF control signal outp...show more -
product
Vacuum Chambers
CV 400/CV 250
The CV 250 and CV 400 are vacuum chambers for altitude flight simulation for avionics instruments such as altimeters, rate of climb indicators and all non pressurised equipment. They are fitted with pneumatic and electric connectors and a quick locking door.
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Automotive & Industrial Cycle Testing System
CV
The CV is Bitrode's economical cycle life test equipment for the network based line of battery laboratory equipment. Designed to work with VisuaLCN Lab Client software, the CV provides standard or fully customized charge, discharge and rest cycles for automotive and industrial batteries. The Model CV is also useful for reserve capacity and charge acceptance testing with recharge.
-
product
Programable Power Supply & Programable Electronic Load
EL-820P
*Digital button control and easy operation*High resolution(20mV, 10mA, 0.1W, 0.1Ω)*Overload prevention function*9 sets programmable memory*4 sets real time display*Voltage range: 1V~63V*Current range: 10mA~15A*Maximum power: 200W*Operation mode: CV, CC, CP and CR*Built in USB interface
-
product
6kW Regenerative DC Electronic Load (CC/CR/CV/CP/CC+CV/CR+CV)
PLZ6000R
PLZ6000R is a DC electronic load that regenerates load power to the AC line. Regular electronic loads consume load power by having semiconductor devices convert it into heat. By contrast, PLZ6000R converts load power into reusable electric power, rather than converting it into heat as is typically done, and feeds this power to the AC line, thereby substantially reducing the amount of waste energy. PLZ6000R is an environment-friendly electronic load that can contribute significantly to your energy saving efforts.
-
product
Software
Production C-V Measurement
Materials Development Corporation
The production software offers a streamlined C-V plotting and bias-temperature stress program with minimumoperator input. A single keystroke begins the measurement.