Filter Results By:
Products
Applications
Manufacturers
4-wire
resistance measurement using an ohmmeter's two each, force and sense leads.
See Also: Resistance
-
product
Capacitive to Digital and Touch Screen Controllers
Are 12-bit successive approximation analog-to-digital converters (SAR ADCs) with a synchronous serial interface and low on-resistance switches for driving 4-wire resistive touch screens.
-
product
Contact Probe for Solar Panels
TP878.1SS.O
Contact temperature probe for solar panel. 1/3 DIN 4-wire Pt100 sensor.
-
product
Contact Resistance Meter
PCRM200S
The Motwane Manufacturing Company
The Motwane make Contact Resistance Meter (Model:PCRM200S) is a digital micro-ohmmeter, specially designed to measure extremely low resistance in micro ohm. The Instrument is based on Kelvin 4-wire connection method for measurement of low resistance.The Current injection is fixed at 100A & 200A. Test information like current injected with measured resistance & voltage drop is displayed with real time data on large LCD with backlit.This User friendly Instrument and it's accessories are housed in easy transportation case. Advanced Windows based software isprovided for data downloading, analysis and report generation. Internal memory of 199 records is provided for onsite data storage withDate & Time stamping & Recalling facility. Thermal printer is the additional feature provided to print the test results.
-
product
Dual MAX31865 PT-100 RTD to Digital Breakout
SEN-30202-PT100
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.
-
product
Electrical 5-in-1 Production Safety Analyzers
Model 19032/19032-P
Electrical Safety Test (EST) Analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.
-
product
Inputs Temperature Data Logger – Pt100
HD32.7
The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000.
-
product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30003-J
Breakout board for the MAX31855J digital thermocouple interface ICs by Maxim. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws. The SEN-30003 is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance (many other level shifters reduce data rates to below 500 kHz).
-
product
Resistance Measuring Equipment
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.
-
product
Resistive Touch Controllers
Analog Devices offers a range of controller ICs for use with 4-wire resistive touch screens. These controllers can be used in human machine interface applications in consumer, automotive, and other products. Analog Devices’ controllers have 12 bits of resolution, SPI/I2C interface options, and low power consumption, making them ideal for use in handheld devices.
-
product
RS232 / RS485 / RS422 Isolators/ Isolated Converters
From 3-wire to 7-wire RS232 isolators, 2-wire RS485 to 4-wire RS422 / RS485 isolators, and USB isolators to USB / RS232 / RS485 / RS422 optically-isolated converters, CommFront has all the industrial-grade optical-isolation devices to protect your assets from the unexpected. If off-the-shelf product does not provide enough security for you, we can even tailor-make the devices, which are customizable right down to the nuts and bolts.
-
product
Serial to GPIB Controller
Model 4895
ICS's Serial to GPIB Controller allows any computer with a serial port to control GPIB devices. Works with RS-232 and 2 or 4-wire RS-422/RS-485 signals. Use to add GPIB Capability to PLCs with serial ports.
-
product
Signal Conditioners
Process transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.
-
product
Soil and Air Temperature Probe
TP32MTT.03.B
Temperature probe with two 4-wire Pt100 1/3 DIN sensors for measuring the soil and air temperature (± 50 mm).
-
product
SparkFun TFT LCD Breakout
1.8" (128x160)
The SparkFun TFT LCD Breakout is a versatile, colorful, and easy way to experiment with graphics or create a user interface for your project. With a 4-wire SPI interface and microSD card holder, you can use this breakout to easily add visual display/interface capabilities to a project as well as providing all the storage you might need for multimedia files.
-
product
SparkFun Triple Axis Accelerometer Breakout
ADXL345
This new version adds two standoff holes as well as an extra decoupling capacitor. The ADXL345 is a small, thin, low power, 3-axis MEMS accelerometer with high resolution (13-bit) measurement at up to +-16 g. Digital output data is formatted as 16-bit twos complement and is accessible through either a SPI (3- or 4-wire) or I2C digital interface.
-
product
temperature Measurement
Educated Design & Development, Inc.
Up to 8 resistance reading channels, 4-wire methodUp to 12 temperature reading chanels, use of Type K, 24 AWG, Teflon thermocouplesIn the Box:8 - data cable (Cat5e) to connect the isolation modules to the Resistance Reading Channels8 - Isolation Module connected between the HOT-30 and EUT (Equipment Under Test) to isolate high voltage8 - Banana Jack Sets (2 red, 2 black), to replace Kelvin Leads in tight places8 - Kelvin Probe Set12 - 72 inch K Type Thermocouple1 - USB2.0 Type A (standard) to Type B USB cable
-
product
Temperature Probe for Outdoor
TP32MT…
Series of Pt100 1/3 DIN 4-wire or T-type thermocouple temperature probes for outdoor/environmental measurements.
-
product
Value-added Module With 4 Terminal Block 4-wire Isolated RS-232/422/485
VAM100
*4 4-wire Isolated RS-232/422/485*Swappable modular design*Maximize I/O flexibility*2kV isolated protection*Designed for tBOX300/500 series*LVD, FCC, EN 50155 and IEC 60945 certified; CE compliant
-
product
Value-added Module With COM/CAN/DIO And 3 PCI Express Mini Card Slots
VAM900
*1 4-wire isolated RS-232/422/485, 1 isolated CANBus 2.0A/B, 1 isolated DIO 8-in/8-out*Swappable modular design*Maximize I/O flexibility*2kV (COM & CANBus)/1.5 kV (DIO) isolated protection*Designed for tBOX300/500 series*EN 50155 certified; CE, LVD and FCC compliant
-
product
Water Conductivity Transmitters
ABB conductivity analyzers are designed to meet the most exacting requirements of our valued customers. The extensive range covers 2 and 4-wire analyzers and single or dual-input devices.
-
product
Wound Component EST Analyzer
19036
Chroma 19036 is the industry's first wound component electrical safety test (EST) analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.
-
product
Current Transformer
CBT4
Shanghai Powoo Industry Develop Group Limited
- Completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - more space in meter can be saved with combined current transformer in comparison to that of the same number of single form current transformers; - HLX-2 is used for 3-phase-3-wire circuits; HLX-3 is used for 3-phase-4-wire circuits;
-
product
CableEye 4-Wire Calibration Verification Board | Cable & Harness Testers
CB52
CAMI Research Inc. (CableEye®)
The CB52 is intended for periodic calibration verification of the Kelvin 4-wire resistance measurement module – an optional, add-on module that may be purchased with any new hipot system, or added to an existing high voltage tester as an upgrade. To ensure that 4-wire resistance measurements remain accurate, CAMI recommends running the verification check every quarter. A 4-wire measurement module that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable measurements.
-
product
Digital Power Recorder
MPR-601W-01
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
product
16-Channel RTD Signal Conditioning Card
ProDAQ 5821
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
product
4-Wire Universal Cable/Harness Tester
LX-760+
Shenzhen Lian Xin Technology Co., Ltd.
The system provides English/Chinese free switch operation interface·4-Wire Measurement
-
product
ANSI X3.28 to Modbus RTU Converter
Model 2399
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.