product
Surface Roughness Meters
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters.When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate analogue signal, which is in proportion to the surface roughness at output end of phase-sensitive rectifier.
-
product
Electronic Ballast Automatic Test Equipment
ATE-1
Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency),...show more -
product
AC-DC Rectifier / Converters
These following AC-DC converters all can provide 3.3/5/9/12/25/24/28/48V etc output. Newly acquired 2U rack mount 48V rectifier is a mature solution for 48V telecom systems.
-
product
P Series Panel Meters
ST-38N
Standard Electric Works Co., Ltd
● DC up to 15A● Case and Composition: Acrylic resin front. ABS case. Four studs mounting. Two studs mounting.● Accuracy :DC : Class 2.0 AC : Class 2.5 Rectifier : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
product
"Stiff Grid" and Parallel Operation AC Generator Excitation Regulator
SVRFP
The Kinetics model SVRFP Exciter/Regulator rectifier is designed and rated in capacity and operating parameters for the application of exciting the fields on an AC generator in parallel with other AC generators and the power system is a "stiff system" in relation to loading. A "stiff system" is a generating system that is of sufficient capacity or the generator is "small" in relation to the system grid, that the AC system voltage under impulse/step loading condition does not require forcing of the generator field to maintain the power grid voltage. Systems are designed with a standard unit service factor to operate within the +10% to -20% nominal voltage rating at 100% current rating.
-
product
AC/DC Power Supplies
At ABSOPULSE Electronics, we specialize in the design and manufacture of heavy-duty custom and semi-custom AC-DC switching power supplies, rectifiers and battery chargers.We can meet any AC to DC input/output configuration requirement, with output power ranging from a few watts to several kilowatts.ABSOPULSE's rugged power supplies are typically designed and built for an operational life of 20 to 30 years in harsh environments.
-
product
Quasi Square Wave Constant Voltage Transformers
Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.
-
product
460V / 18 Amp Load
EL08-460M
For High Voltage UPS Battery Testing and Power Supply testing. This particular Load has been designed to operate with UPS Battery Systems and Telecom Rectifiers and Power Supplies with output Voltages in the range of 307V to 460V and is extremely cost effective.
-
product
48V / 250 Amp Load
EL15-48M
For Telecom Rectifier and Power Supply testing. This particular Load has been designed to operate with Telecom 48V Rectifiers and Power Supplies with output Voltages in the range of 38V to 60V and is extremely cost effective.
-
product
Repair of Six Diode Bridge Assemblies, P/N 5989C
CEHCO is specialist in repair of various rectifier assemblies. One such assembly is shown below:Specifications:- Six Diode Bridge Assembly, P/N 5989C- AC input terminals: (3, 4 , 5)- DC output terminals: (1), POSITIVE and (2), NEGATIVE
-
product
Ampere Hour Meter Module
TE2504
Ampere Hour Meter Module- Model TE 2504 is basically managed for ready setup or the usage can be seen in where the current requirement are low. This one is used which is ready to be applied in the stand alone panel and advanced from all the former models, IM2501, IM2502 and IM2503. These are basically panel mount instruments which are required to rectified in the rectifier or in an independent panel.
-
product
Miller 400D
44550
No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be...show more -
product
Switch Mode Power Supplies-Water Cooled
The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
product
Replacement Selenium Rectifiers
Selenium rectifier stacks are made up of selenium cells, which are mounted together and circuited as required for each application. They are available in configurations to suit all of the rectifier circuits.
-
product
110V / 90 Amp Load
EL12-110M
For Telecom Rectifier and Power Supply testing. This particular Load has been designed to operate with Telecom 110V Rectifiers and Power Supplies with output Voltages in the range of 100V to 135V and is extremely cost effective.
-
product
Rectifier Assemblies for Crane Applications
CEHCO manufactures Transformer Rectifier Assemblies for Crane Applications. We offer standard products and customized solutions.
-
product
P Series Panel Meters
ST-38
Standard Electric Works Co., Ltd
● DC up to 15A● Case and Composition: Acrylic resin front. ABS case. Four studs mounting. Two studs mounting.● Accuracy :DC : Class 2.0 AC : Class 2.5 Rectifier : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
product
Device Thermal Test Systems
Thermal Engineering Associates, Inc.
Thermal test system combines the test and measurement capability of dedicated instruments with the ease of operation and data collecting capability offered by graphical-user-interface-driven software operating on an integrated computer.Diodes (PN, Schottky, LED, varactor, PIN), Stacked Diodes (Hi-V Rectifiers & LEDs), Laser Diodes, Transistors (Bipolar, MOSFET, IGBT) & Diodes, Integrated Circuits (Application & Thermal Test Die).
-
product
Electric Load
PT04-250-63
For Telecom Rectifier and Power Supply testing. *0 to 63A up to 250V, power limited to 1,900 Watt *CC, CP, CR and CV as standard *63A available Load down to 5.3V
-
product
F Series Panel Meter
ST-70U (Four studs mounting)
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
product
Voltage Rectifier
A voltage rectifier, designed and manufactured by Monex GeoScope Pty. Ltd., has been added to the terraTEM suite of products. The voltage rectifier has been designed to provide 6 kW, 120 V, 50 A output and is the ideal rectifier to guarantee the necessary stable, ripple free current for the full range of Monex GeoScope’s transmitters. This includes the internal transmitters for the terraTEM24 (50 A, 120V), terraTEM (15 A, 24 V) and the terraTX-50 external tra...show more -
product
Power Discrete Tester
Mostrak-2
M2 test system has multiple test generators which cover static and dynamic test procedures. It is our first truly modular tester which allows for the system to be upgraded and expanded when needed. M2 are designed to get the tester as close as possible to the handler interface and operator at the highest possible speeds. M2 is capable of HV (3 kV) and LV (600A) testing and has dynamic switching capabilities up to 1200V. MOSTRAK systems can test the following device types: MOSFET, IGBT, Bipolar transistor, Diode - rectifiers, Thyristor (SCR) - Triac, Linear voltage regulator (VReg), Transient voltage suppressor (TVS).
-
product
M Series Panel Meters
ST-118T
Standard Electric Works Co., Ltd
● M Series all up to 15A● Case and Composition:Acrylic resin front and ABS resin case. Four studs mounting.● Accuracy:Moving coil type : Class 2.0 Rectifier type : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
product
5000 AMP DC Rectifier - Air Cooled, P/N 6037C1
Air Cooled SCR Controlled Power Supply, 50 KW, P/N 6037C1Input: 480 VAC, 60 Amps, 3 PH, 60 HzOutput: 6 to 10 VDC, 5000 Amps maxContactor and overload relay are installed for protectionStart / Stop capabilityEPO capabilityManual voltage control and current limitOutput voltage and current are displayed on the voltmeter and ammeterIndoor enclosure, 68″H x 65″W x 36″DAll input/output connections are inside the enclosuresEstimated weight: 1000 lbs.
-
product
48V / 200 Amp Load
EL12-48M
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with Telecom 48V Rectifiers and Power Supplies with output Voltages in the range of 38V to 60V and is extremely costeffective.
-
product
F Series Panel Meter
ST-70U (Three studs mounting)
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
product
Ammeter
AC Rectifier Type Coil Meter
measures the alternating voltage and current with the help of rectifying elements and permanent magnet moving coil type of instruments. However the primary function of rectifier type of instruments work as voltmeter. Now one question must arises in our mind why we use rectifier type of instruments widely in the industrial world though we have various other AC voltmeter like electrodynamometer type instruments, thermocouple type instruments etc? The answer to this question is very simple and is written as follows.
-
product
Roughness Tester
Compatible with four standards of site to measure surface roughness ofvarious machinery-processed parts, calculate corresponding and clearly display allmeasurement parameters. When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate analogue signal, which is in proportion to the surface roughness at output end of phase-sensitive rectifier.
-
product
Resistive & Capacitive AC Load Bank
RCD
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
product
Load Banks
EL08 Series
*Rectifier Test 8kW*All of our Load Banks are continuously rated for Power and Current.