Filter Results By:
Products
Applications
Manufacturers
Ballast
Balance the current flow to lamps.
-
product
Electronic Ballast High Frequency Parameters Tester
UI2002A
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
product
Input Characteristic Analyzer of Electronic Ballast
UI2001
• 4 display windows for V (600V), A (2A), W, PF/Hz • THD, 0 to 39th harmonic components • Accuracy: ± (0.4% reading + 0.1% range + 1 digit) • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
product
LED Lighting Drivers
Renesas' dimmable AC mains LED driver with PFC and primary side regulation provides all of the features required for high-performance dimmable LED ballast designs and supports AC or DC input, isolated or non-isolated flyback and boost topologies.
-
product
Light Compensation Capacitor
CBB80
Designed for lighting applications such as fluorescent lamps,high-pressure mercury vapor lamps,sodium lamps,and metal halide lamps. The capacitors are used for power factor compensation of transformers and magnetic ballasts in lamps with a frequency of 50Hz or 60Hz,which makes the power factor to achieve cosφ 0.9. The temperature
-
product
Output Characteristic Analyzer of Electronic Ballast
UI2002
• Measure lamp voltage, lamp current, lamp power, oscillatory frequency, filament current, guided cathode current, and crest factors • Measure changing curves and values of startup lamp voltage, lamp current, filament current, cathode current from 0 to 5 seconds, as well as the pre-heat time • Accuracy: Class 2 • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
product
Thermally Protected Ballast Heating Test Chamber
TPB-UL935
Working room dimension: 610×610×610mm• Temperature range: RT+10℃~+100℃• Materials of inner and outside chamber: Senior stainless steel• Insulation Material: Ultra-fine glass wool insulation material• Heater: Dedicated strip heater (heating surface area of 300 × 40 mm), each group three hundred watts, a total of four groups, with the power supply in parallel.• Special wooden test sample holder• Third gear temperature measurement points (at any time monitoring and conversion)
-
product
MOS Transistor Selector
UI9610
MOS with superior performance has now been widely used in electronic ballasts, energy-saving lamps were. But power MOS test screening, matching problem. It is difficult due to a lack of corresponding inspection means that many enterprises do not have to engage seriously in quality control as well as the effect of product consistence and reliability. The equipment in a unique program designed to solve the power MOS test problem containing micro-processing, intelligent a few significant simple application.
-
product
Magnetic Core Selector
UI9702
• Measure relative value of μm, Bs, Br, Hc integrated factor• No need of wiring, direct testing, being convenient• Automatic selecting, out of limit alarming, freely setting of the selecting limit• Driving current for test: 0-2A, frequency for test: 20-50kHz, both continuously adjustable, Comply with actual working situation of electronic ballast• No need of adjusting the instrument every day• Digital display, easy to read, simply and quickly to operate• Print B-H curve
-
product
Marine Ballast Water Analyzer
9017
Developed specifically for the demands of marine environments, OI Analytical's new Model 9017 Marine Ballast Water Analyzer was engineered to meet the stringent United States Coast Guard (USCG) standards. The 9017 monitors and controls total chlorine and residual oxidants around the clock, while connected to a Ballast Water Management System with user-programmable cycle times and alarms.
-
product
FLuorescent Lamp And Ballast Tester
2210-20
Milwaukee Electric Tool Corporation
The Milwaukee 2210-20 Fluorescent Lighting Tester is a new to world tool that tests fluorescent lighting fixtures and cuts troubleshooting time in half. The Fluorescent Lighting Tester delivers complete Lamp, Ballast and Pin testing. Test Lamps before or after installing, and test without dismantling the fixtures.Recognized for its innovation, the 2210-20 Fluorescent Lighting Tester will dramatically improve the productivity of professional electricians and maintenance technicians. Instead of a “replace and hope” strategy, users can test their lighting fixtures faster and easier. The 2210-20 Fluorescent Lighting Tester solves a top residential, commercial and industrial application.
-
product
CFL Testing Instruments
CFL testing instruments of Lisun Group includes: High Frequency Fluorescent Lamp Test, Adjustable Reference Ballast, Digital Torsion Meter, Multiplex temperature tester, Lamp cap gauge, etc.
-
product
Electronic Ballast Automatic Test Equipment
ATE-1
Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.
-
product
Electronic Ballast Analyzer
WT3000
• It has 8 windows to display each parameter of input and output characteristics • Frequency response for testing input current up to 1MHz, suitable for precise testing of various kind of electronic ballast • WT3000 has expanding analysis for envelope wave. • Symmetry analysis for envelope wave’s crest factor of lamp current • Sampling at ultra-high speed, dynamic analysis single frequency curve, highest sampling frequency is up to 10MHz • Portable with built-in chip micro-processor, particular suitable for development and spot production • RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7
-
product
Electronic Ballast Production Line Tester
UI2000-OK
• Eight windows for displaying input characteristics, output characteristics, convenient for comparison and analysis. • Frequency response for testing input current up to 1 MHz, suitable for precise testing of various kind of electronic ballast. • High speed testing, finish testing input and output characteristics within 1 minute. • Portable with built-in chip micro-processor, particular suitable for development and spot production. • Parameters, waves and curves of input, output and startup can be printed. • Communicating with PC, special software provided and both Chinese version and English version available. Run in WINDOWS3.2, WINDOW95 or WINDOWS98, nice interface between people and computer, easy to operate.
-
product
Electronic Ballast Tester
WT4000
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.
-
product
Online OK Tester for Electronic Ballast and CFL
WT-1
• Test 6 pieces at one time, suitable for mass testing in assembly line. • Measure parameter: Vrms, lrms, W, PF. • Freely set upper and lower limit for lrms, W, PF, alarm when value out of limits. • Freely set test duration in range: 0-99.9s, tested data automatically locked. • Test range: 1) Vrms: 10.0-300.0V 2) lrms: 5-999mA 3) W: 0.1-300.0W 4) PF: 0.0001-1.000 • Accuracy: 0.5% • Digital display on 6 windows is easy to read • Print port and communication port available (optional)
-
product
Multi-points Temperature Tester
Shenzhen Chuangxin Instruments Co., Ltd.
TP series of multiplex temperature meter is a kind of instrument which suits to real time monitor and trace multi-points temperature simultaneously. With the features of Simplified operation, high precision and reusable thermocouple, it is widely applied in electronic ballast, motor tools, lighting fixtures and household appliances. The application software records and save the temperature rising curve in real time for analyze purpose.
-
product
Multiplex Temperature Meter (8 ,16, 64 Channel)
TP-1
Shenzhen Chuangxin Instruments Co., Ltd.
TP series of multiplex temperature meter is a kind of instrument which suits to real time monitor and trace multi-points temperature simultaneously. With the features of Simplified operation, high precision and reusable thermocouple, it is widely applied in electronic ballast, motor tools, lighting fixtures and household appliances. The application software records and save the temperature rising curve in real time for analyze purpose.
-
product
Ballast Water Monitoring Systems
Ballast water is essential for safe and efficient shipping operations and stabilizing steel-hulled vessels at sea. It provides a variety of critical functions, such as maintaining balance, stability, and structural integrity on non-cargo voyages or when cargo is unloaded. Ballast water is also used to compensate for fuel and water consumption during at-sea operations.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
PC Vibration Measuring System VibroMetra
Metra Mess- und Frequenztechnik in Radebeul e.K.
*The system was designed for typical tasks of vibration measurement. No ballast by unwanted functionality. *The system is modular making it upgradeable and particularly economic with fewer channels.*The necessary hardware is very compact which makes it particularly suited for mobile use.*Short installation and training time. After a few minutes you may start with the first measurement.*Off-line measurement: VibroMetra permanently saves the raw data stream of the sensor signal in the background. By this means you may analyze your measurement later again with other settings or other software instruments.*Data export as graphics, text or binary file
-
product
Water Quality Monitoring Systems
We provide instrumentation, test kits, and chemical reagents used for monitoring water quality in a variety of applications. Primary applications used within our industry include drinking water, wastewater, and ballast water.
-
product
HID Ballast Tester
WT2000-HID
• Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz
-
product
Lamp Testers
is a pocket-sized tool that takes the guesswork out of troubleshooting fluorescent lighting systems. Quickly determine by process of elimination, whether it’s the bulb, pins, voltage or ballast.
-
product
HID Electronic Ballast
Shanghai Yiya Electronic Instrument Co., Ltd.
Applicable to illumination of marketplace, office illumination, home illumination, architectural illumination.
-
product
Integrated Function Tester for Inductance Ballast
UI2001B
• Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available for PC, running under Windows98/2000/XP/Vista
-
product
Electronic Ballast Tester
WT5000
WT5000 is the updated version of WT3000 with a super LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GB/T15144-2005, GB/T17263-1998 and so on.
-
product
CCFL Ballast Tester
WT2000A-CCFL
This tester is specially designed for analyzing the electrical characteristics of CCFL Electronic Ballast, meets the test requirements in international standard• Input characteristics analysis: measure Vrms, Irms, W, PF, Hz, phase angle Measure THD, 0 to 39th harmonic components, Accuracy: ±(0.4% reading+0.1% range+1 digit)• Output characteristics analysis: measure lamp voltage, lamp current, lamp power, oscillatory frequency, crest factor of lamp current, Accuracy: Class 2• Interface RS-232C provided for easier communication with PC for printing test report
-
product
Electronic Ballast Tester
LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards
-
product
Lighting ICs
Based on its 30-year experience in power conversion and high-voltage technology, ST offers a wide portfolio of solutions for electronic ballasts, ranging from high-voltage ballast controllers for analog solutions (with or without embedded PFC), to complete power management units with integrated drivers and voltage regulator for digital platforms.