Filter Results By:
Products
Applications
Manufacturers
RCD
Residual Current Device
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
Loop Meter
MZC-304
# Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,
-
product
PAT and Installation Verification Unit
PowerCheck 1557
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
product
PAT Check Box
369A910
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
product
Require External Wireless Module
Multifunction Loop Tester
*Measure AC / DC Voltage upto 750V (AC) / 1000V (DC)*Measure resistor, diode, capacitor*Continuity check*Non Contact Detector NCD (ACV)*Single Probe Test, identify Live / Neutral (SPT)*Measure Frequency and Duty cycle*Socket test*RCD test*Loop test
-
product
Short Circuit Loop Impedance Meter
AMZC-304
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
product
RCD Tester
CZ20053
Protect yourself and your employees by ensuring that your portable electrical appliances and equipment are tested for electrical safety to AS/NZS 3760:2010 with the RCD Tester. The CZ20053 Aegis RCD Tester is an essential piece of equipment for every workplace.
-
product
Volt Tester
VT750LCD
The VT750LCD is a compact reliable robust automatic voltage tester up to 750V. The testers can measure and indicate the exact voltage (AC/DC), phase indication, phase rotation and continuity, RCD, and resistance via an LCD.
-
product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
product
Combo Insulation And RCD Tester
CZ20073
New in the Aegis product range is this combination of 2 products in one – no longer do you have to carry individual testers for each individual job ! Combining IR and RCD testing into the one tester is the focus of the CZ20073 with the added bonus of continuity testing and voltage measurement completing the spec.
-
product
Multifunction Testers
1662
The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
-
product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
product
Voltage Tester With Wire Stripper
7122A
Peaceful Thriving Enterprise Co Ltd
The product can measure AC voltage 10V to 1000V and DC voltage 7V to 1000V with polarity indication. All testing results will be displayed by LCD. This product can also measure continuity and RCD. Eventually, for the convenience of wire stripping and cutting, this product has combined the function of wire stripper.
-
product
RCD Loop Line
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
product
Socket Tester c/w Buzzer
DL1092
Clear visual and audible indication RCD test of 30 mA RCD (max time 300 ms) Touch voltage to check for extraneous voltage on earth Compact, durable design in compliance with BS EN 61010
-
product
RCD Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.
-
product
Electrical Test Equipment Calibrators
The industry leading series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers.
-
product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
product
230V AC Socket Tester With RCD Test (For UK)
1944
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*RCD Test.*30mA leakage current measurement.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon idnicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1.5W*Frequency: 50Hz
-
product
Digital RCD Tester
1112 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Very low consumption.● 50Hz and 60Hz operation.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off. ● Backlight function. ● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
product
Digital RCD Tester
1612 EL
Standard Electric Works Co., Ltd
●Microprocessor-controlled●Extra large LCD (78 × 67mm)●Very low power consumption●50Hz and 60Hz operation●Accurate digital readout of disconnection time●Over temperature protection●Over voltage protection●Fuse protection●Zero crossing circuitry permits testing at 0° or 180°●Auto power off●Backlight function●Wiring polarity indicator●Measures voltage between Line and Earth before testing●Frequency measurement indication
-
product
Digital RCD Tester
1113 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Very low consumption.● 50Hz and 60Hz operation.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off. ● Backlight function. ● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
product
Digital RCD Tester
8012 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Extra large LCD(78 × 67mm).● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off.● Auto off and off override.● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.●Frequency measurement indication.
-
product
Digital ELCB (RCD) Tester
1811 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).
-
product
Digital ELCB (RCD) Tester
1813 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
-
product
Digital ELCB (RCD) Tester
2712 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
product
Digital ELCB (RCD) Tester
1812 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto-off and off override.● Polarity Trip indicator (Positive of Negative Phase).● Wiring polarity indicator.● Measure voltage and frequency between Line and Earth before testing.
-
product
EV Test Equipment
Di-LOG’s New EV Test Equipment Range which includes the DL9100 series MFT incorporates the DL9120 and DL9130EV with both products boasting DC capability, paving the way for a host of tests-specific to the *EV and PV sectors, mainly the ability to conduct a Type B (Pure DC) RCD test.
-
product
Recorder Carrier Device
RCD
The RCD is a carrier signal demodulator for SCADA and Fault Data Recording. the RCD demodulates the carrier to indicate the presence of a relative level of a singal
-
product
Digital RCD Testers
Used to detect whether the RCD in the circuit can be triggered normally.