Filter Results By:
Products
Applications
Manufacturers
-
product
Compact Vibration Generator
The compact vibration generator is used for calibration of a vibrometer, measurement of mechanical impedance, excitation source for modal analysis and reliability test of a small light specimen. In particular, EMIC uses the world's first ceramic armature for the 512-D and 513-D vibration generator,making it possible to excite up to high frequency of 30 kHz (513-D can excite up to 24 kHz).
-
product
Compensating Reactor
The compensating reactors are accessories for the CTS-12KSA/ACTS-12K Capacitance & Tan Delta Test Set. The use of one or more compensating reactors increases the capacitance that the internal power supply can excite to conduct measurements. As the measuring range of the CTS-12KSA / ACTS 12K exceeds the kVA rating of the internal power supply, one way of using the test set over its entire measuring range is to form a resonant circuit with the test sample. The use of one or more compensating reactors forms partial resonating circuit with the test specimen, thereby reducing the power supply requirement.
-
product
Concrete Surface Resistivity
Surf
Giatec Surf™ is a laboratory test device for rapid, easy and accurate measurement of the surface electrical resistivity of concrete based on the four-probe (Wenner-Array) technique. The Surf™ patented technology automatically measures resistivity around the concrete specimen using four channels of 4-probe array (located at 90° from each other). The PC software generates the required reports according to the standard specifications.
-
product
Crease Recovery Tester
TESTEX Testing Equipment Systems Ltd.
Crease Recovery Tester, to determining recovery properties of fabrics by creasing in a loading device for a predetermined time using a weight suitable for the test method specified (BS/ISO/AATCC), After transferring the specimen to the clamp of the tester, the specimen is allowed to recover and the angle of recovery recorded. Fabric Crease Tester complies with ISO 2313, AATCC 66, BS EN 22313, etc.
-
product
Crease Recovery Tester
TF110A
TESTEX Testing Equipment Systems Ltd.
Crease Recovery Tester & Loading Device, to determine the recovery properties of fabrics by creasing in a loading device for a predetermined time using a weight suitable for the test method specified (BS/ISO/AATCC). After transferring the specimen to the clamp of the tester, the specimen is allowed to recover and the angle of recovery recorded.
-
product
CT-NANO
The CT-NANO is a fully operating scanning electron microscope with capabilities of Nano-CT measurements on specimen like light-metal-alloys and fiber composites.
-
product
Data Logger for Extremely Low Temperature
DSR-ELT
Special probe using military industrial technology supports measuring temperature ultra low to -196 Original fittings for sensor connection, ensures 100,000 plugs Support single DSR connecting to PC via USB interface, and multiple DSR grouped in RS485 or LAN networking for central management Suitable for medical refrigerator, biological specimens preservation, scientific research and other applications
-
product
Data Logger for Ultra Low Temperature
DSR-ULT
Special probe using military industrial technology supports measuring temperature ultra low to -100 Original fittings for sensor connection, ensures 100,000 plugs Support single DSR connecting to PC via USB interface, and multiple DSR grouped in RS485 or LAN networking for central management Suitable for medical refrigerator, biological specimens preservation, scientific research and other applications
-
product
DC Resistance or Conductance of Insulating Materials
ASTM D257
These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.
-
product
Event Detectors
105/106 Series
The 105/106 Series Event Detectors are the most versatile Event Detectors in the product line. These Event Detectors monitor the electrical resistance of up to 128 simple continuity loops, each comprised of single or multiple specimens under test. Each test specimen is continuously monitored while a selectable DC sense current is passed through each channel test-loop; resistance changes exceeding the selected threshold are recorded as an event. Minimum Event Duration, Channel Current, and Threshold Voltage settings can all be independently configured. 105 and 106 Series instruments are electrically identical, with the difference simply that the 105 offers four, 32-channel board slots and the 106 offers only one. Thus the 128-105 is equivalent to four 32-106 Event Detectors.
-
product
Film Impact Tester
SKZ146
The tester is designed according to GB 8809, ASTM D 3420 applied to test the impact ductility of plastic, rubber, and foil, etc. It impacts and punctures the specimen in the certain impact speed through the semicircular impact anvil so that to test the energy that expended. The energy is the standard to evaluate the impact energy of the anti-impact of the specimen.
-
product
Flexible Implantable Microprobe
IT-1E
IT-1E Flexible Implantable Microprobe - For ultra fast measurements and for use on micro-size specimens. Similar to our most popular IT-18 microprobe but the sensor bead is exposed, resulting in the same ultra-fast response time of the IT-23 but with the Teflon™ sheath strength of the IT-18. Time constant 0.005 seconds. Tissue Implantable with a 18 gauge needle (supplied). Rather fragile at tip. Coated in Teflon™. Maximum Temperature 150°C. Isolated. Probe tip diameter .011", sheath diameter .025'' . 3 foot lead.
-
product
Flexometer
EKT-2002GF
By means of applying constant load and compression frequency to the test specimen, this instrument could help the user to understand the history of Heat Built-up and dynamic fatigue poeperties of rubber compounds. For example, while tests the tire compound, it could provide the information of rolling resistance. Pt100 temperature sensor, temperature controller in PID parameters control, and air circulator are adopted to ensure the stable temperature control.
-
product
Gas Fume Chamber
TF417
TESTEX Testing Equipment Systems Ltd.
A specimen of the textile and the test control fabric are exposed simultaneously to oxides of nitrogen from burnt gas fumes until the control shows a change in color corresponding to that of the standard of fading. The change in color of the specimen is assessed with the standard gray scale for assessing change in color.
-
product
Geotextile Abrasion Tester
TG060
TESTEX Testing Equipment Systems Ltd.
The specimen is fixed on the platform, a specified abrasion material rubs the specimen under the specified pressure and friction action, determine the tensile strength after abrasion test, the percentage of loss of the tensile strength is reported as the resistance performance of abrasion.
-
product
Geotextile Opening Size Tester (Dry Sieving)
TG020
TESTEX Testing Equipment Systems Ltd.
A geotextile specimen is placed in a sieve frame, and sized glass beads are placed on the geotextile surface. The geotextile and frame are shaken laterally so that the jarring motion will induce the beads to pass through the test specimen. The procedure is repeated on the same specimen with various size glass beads until its apparent opening size has been determined.
-
product
Gold Detectors
Be prepared to dig deeper than ever before! With a Minelab Gold Detector you''ll find the elusive gold nuggets that others are missing! Minelab Gold Detectors are the FIRST CHOICE for: Professional gold prospectors, Small scale artisanal mining, Serious holiday gold prospecting, Weekend enthusiasts, Gold specimen collectors.
-
product
Heating Microscope
Heating microscopy is a non-contact technique that, based upon an advanced image analysis of a specimen subjected to a thermal treatment reproducing industrial firing conditions, identifies several characteristic shapes and related temperatures key to the optimization of manufacturing processes in ceramics, metals, and alloys.
-
product
High and Low Temperature Thermal Shock Chamber
HLST-500D
The specimen is placed in test chamber specimen which cannot be placed in high temperature chamber or low temperature chamber. High temperature chamber pre-heats the air and low temperature air chamber pre-cools the air. When doing the test of temperature changing from high to low, the low temperature chamber will blow the pre-cooled air to the test chamber. Then, the air in test chamber will reach your target temperature in several minutes (“recover time”). When doing the test of temperature changing from low to high, the high temperature chamber will blow the pre-heated air to the test chamber. Then the air in test chamber will reach your target temperature within the recover time.
-
product
High-end Transmission Electron Microscope
CryoARM
JEOL announces the latest member in its family of high-end transmission electron microscopes, the CryoARM. This highly automated TEM is designed for unattended operation and high throughput imaging of cryo-EM specimens. The CryoARM was initially introduced to a select audience at the 2016 Gordon Research Conference in Hong Kong, M&M 2016 in Columbus, OH and EMC 2016 in Lyon, France. The CryoARM is a dedicated cryo-TEM, based on the highly successful JEOL ARM (Atomic Resolution Microscope) series, an ultrahigh performance, highly stable platform considered to be the "best-in-class" TEMs. The development of the CryoARM was accomplished in collaboration with leading Life Science researchers.
-
product
Insect Rearing Rooms
Standard walk-in incubators or coolers used in the rearing of drosophila and other biological organisms often end up being problematic for a number of reasons. The acids inherent in the rearing of many specimens or their food can quickly corrode a standard refrigeration evaporator. High humidity exacerbates the issue, as droplets of concentrated acid will collect on the cooling components.
-
product
Lab Shaking Dyeing Machine
TD230
TESTEX Testing Equipment Systems Ltd.
This machine is a professional equipment for sample dyeing and washing test at room temperature in weak alkaline environment or conventional conditions, for fabrics, fiber or yarn. Ultra quiet design and greatly enhances levelness of specimen dyeing.
-
product
Low-Temperature Impact Device
DWC-1
This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally
-
product
MESA Vibration Control
MESA tests are specifically required when the unit under test is too heavy or too big and exceeds the capabilities of a single shaker. In a MESA application, multiple shakers provide excitation to the test specimen in a single axis. Different relations like same magnitude and phase for drives, different phase for drives, different magnitude and phase for drives, can be set for this MESA test.
-
product
Micro-Surface Microprobe
ICT-4
ICT-4 Micro-Surface Microprobe - For use on integrated circuits and other micro specimens. 0.013'' diameter .5'' straight stainless steel shaft; slightly protruding sensor bead to facilitate temperature probing. 5'' tubular handle fits micro-manipulators. Maximum intermittent temperature 200°C, continuouse use 100°C, Time constant 0.025 Seconds. 5 foot lead. Not isolated.
-
product
Mini Cloud & Pour Point Analyzer
OptiMPP
The automated OptiMPP provides highly accurate cloud and pour point results using only 0.5 ml sample. Simply place the sample in a disposable vial into the 20 specimen sample changer and press the OK key. No special programming or expected point is required. Results are available in 20 minutes for a -30ºC pour point.
-
product
Needle Microprobe
MT-29/3HT
Fast-response 29 gauge needle probe, (needle length is 3 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Needle Microprobe
MT-23/3HT
Fast-response 23 gauge needle probe, (needle length is 3 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Needle Microprobe
MT-23/5HT
Fast-response 23 gauge needle probe, (needle length is 5 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Needle Microprobe
MT-29/5HT
Fast-response 29 gauge needle probe, (needle length is 5 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.