- Pickering Interfaces Inc.
product
PXI Fault Insertion / Signal Insertion Switch Modules
Pickering's PXI Fault Insertion / Signal Insertion Switch Modules feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system. Two switching topologies are available: *Single signal paths with series switches and switches to connect to one or more fault buses*Pairs of signals with series switches, shorting switches between the signal pairs and switches to connect either signal to an external fault input.
-
product
20Hz Injection Kit Monitoring System
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
240V Socket Tester Check Plug
CP501
The most popular socket tester available - detects 28 fault conditions.
A quick and easy way to ensure that 13A sockets are correctly wired, indicated by 3 bright long life LEDs.
Wiring faults are indicated by one or more of the LEDs failing to illuminate, with the pattern of lit LEDs indicating the type of fault detected. This fail-safe system means that any LED not lit indicates a fault. The robust ABS housing has a sculpted shape for easy removal and there is a look up chart on the tester for quick fault diagnosis.
The plug induces less than 5mA of earth leakage, well below RCD trip thresholds.
-
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault ...show more -
product
Current Clamps and Sensors
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
product
DC Earth Fault Locator
GFL-T + GFL-R
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
product
Current Protection Relay
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Line Indicators
LineTroll
Fault Passage Indicators to locate short circuit and earth faults.
-
product
Medical Leakage Current Tester
2675Y
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable...show more -
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-60NK
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
20Hz Generator
Signals & Systems India Private Limited
In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.
-
product
Socket Tester with RCD Tripping
Shanghai Beha Electronics Co., Ltd.
*Mains wiring polarity check.*ELCB/RCD testing.*Measuring ear for line current.*Measuring ear for leakage current.*Helps calculate insulation resistance.*Helps calculate power consumption.*Helps fault finding of standing earth fault.*Fused main adapter.*Appliance testing (with the ad of a clamp meter).
-
product
RCD Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD tr...show more -
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20MH
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Convenient +5V single polarity power supply
-
product
Digital LOOP/PSC/EARTH Tester
1824 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays...show more -
product
DC System Earth Fault Detector
PDF1000 / 781
Wuhan Huatian Electric Power Automation Co., Ltd.
Our company's DC system grounging fault tester is a new generation of products. It can be applied to dc system measurement of any voltage level.
-
product
Earth Fault Detector
K-3838
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2310
CableTroll 2310 is an indicator for detection of earth faults (PtG) on multi-core and single core cable terminations. The unit uses NorTroll type current sensor (CT)
-
product
Multi-purpose Tester
DEL-101
Standard Electric Works Co., Ltd
● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.
-
product
Ground-Fault Products for Solidly Grounded Systems
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2320
CableTroll 2320 is an indicator for detection of Earth faults (PtG) and short circuit (PtP) faults on multi-core and single core cable terminations. The unit uses NorTroll type current sensors.
-
product
Cable Indicators
CableTroll
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
product
Earth Fault Indicator
The Sensorform Range of Earth Fault Indicators detects earth faults & short circuit faults on underground cables. A number of options are available for enclosure type, power source, indicator type, reset method, trip-level selection, and remote indication.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Multifunction Instrument
COMBI521EV
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Detection of Earth Faults (PtG) and Short Circuit (PtP) Faults
CableTroll 2330
CableTroll 2330 is an indicator for detection of earth faults (PtG) and short circuit (PtP) faults on multi and single core cable terminations. The unit uses NorTroll type current sensors.
-
product
Multifunction Tester
EASYTEST
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.