ROSS ENGINEERING CORPORATION
ROSS ENGINEERING CORPORATION of Campbell, California, designs, tests and manufactures High Voltage Relays, High Voltage Probes, and High Voltage Voltmeters.
- (408) 377-4621
- info@rossengineeringcorp.com
- 540 Westchester Drive
Campbell, CA 95008
United States
Filter Results By:
Products
Applications
-
product
Stored Energy Solenoid Drivers
B-1014
The remote contact controlled HCA Series and the SCR controlled HCB Series of Stored Energy Solenoid Drivers produced by Ross Engineering Corporation are used for high speed opening or closing of Ross Circuit Breakers and Contactors. They perform high speed microseconds to milliseconds actuation of various electromechanical devices. The units feature minimum internal time delay, trigger signal overload protection, and up to 3000 joules of energy storage.
-
product
Hi-Z HV AC Voltmeters
B-1013
*25kV, 50kV or 100kV Meter with integral line to ground Probe*Phasing or line to line with additional Probe*Optional 6ft or 9ft Collapsible Hotsticks*Voltage source for testing Voltmeters and Probes*Optional test point contamination indicating Megmeter®*High voltage cable clamps or hooks*Heavy duty carrying case
-
product
HV Rotary Switches
B-1003
A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use. In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation. G-7 silicone glass is used for special applications where RF or high temperatures are involved. Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force. This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions. Ratings to 150kV, to 200A. When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater. In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional). Each unit is either manually or electrically operated. One SPDT contact is standard on most units. The auxiliary contact is used as an interlock for protection against "Switching Hot".
-
product
Hi-Z HV Safety Voltmeters
B-1013-4
These Hi-Z® HV Safety Voltmeters are for Power Lines, Electric Cars, Electric Trolley and other High Voltage AC & DC detection and measurement. Emergency Crews can use these voltmeters to detect voltage presence warning. They will accurately measure AC and DC voltages.
-
product
HV Probes & Multimeters
B-1010, B1010-A, B-1012, B-1012-A
HV Probes and Voltmeters for oscilloscopes, DVMs, recorders. HV DC, AC & Wideband DC-10MHz. Safety probes for any scope, digital display or recorder. Also available complete with large 4½ digit display 0.01% to 5% DC/AC accuracy digital voltmeter, with safety handles for OSHA recommended personnel clearances. With attached or separate digital display or multimeter 0.00001V to 400kV. HV Digital Multimeters. Wideband DC-10MHz. VMD2A 4½ digit portable meter has accuracies to 0.01% DC, 0.1% 50/60Hz, 3% DC-1MHz, 3dB to 10MHz. True RMS, Avg, True +PK, -PK, PK to PK, 0.2 microsecond, 1/2 sine single pulse capture & hold. 0.00001V - 1000V DC or PK AC and for use with HV Probes to 400kV and Voltage Dividers to 1,000,000V. Has 2V output to scope, recorder. To 1000kV with HV divider, DC-10MHz.
-
product
HV Voltage Dividers
*DC up to 10MHz*1kV to 1,200kV DC or PK AC*To 1,875kV Impulse*To ±0.01% DC Accuracy Accredited*To ±0.2% AC Accuracy (50/60Hz) Accredited*To ±3% DC-1MHz Wideband*±3dB 5 to 30 MHz*Compact & Lightweight*For Oscilloscopes*For Recorder*For Digital Multimeters*Very Partial Discharge/Low Corona*Very Low Phase Shift*Resistive*Capacitance*Compensated Wideband*Indoor & Outdoor*Electronic and Power Class*Match Wideband Differential*High Voltage Power Quality Instrumentation
-
product
Hi-Z Probes
B-1012-B
High Voltage Probes for Very Low Current Power Supply Voltage Measurementto 120kV, such as Electrostatic Paint Spray Applications...
-
product
HV Reed Relays
B-1001-H
*5kV to 15kV Peak Test*3A Continuous*50VA Max Interrupt*NO, NC, DT, Single & Multi-Pole*Safety Encapsulation*HV Leads Available*Compact *Long Life*High Vibration / Shock Resistance*Maximum Creep distance between HV & Actuators Terminals *Tapped base, Turret or Hook terminals, PC Board mounting, Quick disconnect or HV leads available
-
product
Coaxial Cable Drivers & Amplifiers
B-1020
*Wideband: DC to over 30MHz*Maximum Output: to 10V PK, 20V PK-PK*Maximum Input: ±5V to ±200V PK-PK as required. Also to 900kV PK with Ross Voltage Divider*Signal Isolation: 500,000 Ohm 450V PK*Input Impedance: Up to 2 Megohms*Load Impedance: 50 Ohm or greater*Power Source: AC or Optional Battery*Will drive over 500 Feet of Coaxial Cable
-
product
HV Calibration
B-1027
Ross Engineering Corporation’s High Voltage Calibration Lab provides high accuracy capability for conducting tough reliability tests on all our high voltage devices. In this facility we test and calibrate HV Relays, HV Dividers, HV Probes, Spark Gaps, our Fiber Optic Systems, and HV Digital Voltmeters up to 450kV. We provide our own in house test lab to ensure Ross products meet or exceed required safety standards as well as our own high standards of dependability, long life and quality. Our technicians use test equipment calibrated by or traceable to National Institute of Standards and Technology or other national metrology institute to provide the highest in testing accuracy.
-
product
Three-Phase HV Vacuum Contactors & Circuit Breakers
B-1005/6
*Three Phase*Upright or Low Profile for High Reliability*½ to 2 Cycle Trip & Interrupt*208V to 38kV Operate*200 to 1,200A Continuous*2,000 to 28,000A Interrupt*Line or Energy Storage Close & Trip*Ideal for High Power Electronics*High Speed Sealed Arc Interrupting*High Speed Crobar Shorting*Compact, Light Weight*Long Life*Minimum Reignitions*Minimum Restrikes
-
product
HV Spark Gaps
B-1015
*Spark gaps are enclosed in dust tight transparent enclosures with replaceable non-melting carbon spheres, up to 88kV PK.*Above 88kV, open style with hollow aluminum spheres is standard.*Applications for these units include over-voltage limiting, voltage measurement, capacitor discharge, and pulse forming.*Horizontal unit housings are removable.*Vertical unit housings are not removable.*Micrometer Vernier adjustment is standard for maximum accuracy on most models. Economy units without micrometer Vernier adjustment are available as an option.*Insulation to ground is available at standard and optional levels.*Spark gaps to 370kV, with motor operation available.
-
product
Voltage Level Sensor / Interlock
B-1011-G
For limiting, setting or indicating voltage levels of power supplies, required charge level for energy storage capacitors, and voltage level interlocking.
-
product
High Voltage Relays
B-1001
Air insulated types for isolating loads, tap selections, safety discharge & grounding to help meet OSHA and other safety regulations. Ratings from 1mA to 800 amps continuous, to 100,000 amps capacitor discharge. Peak 1 minute test voltages from 5kV to 300kV. Single or Multipole. Auxiliary contacts are optional on all types. Options include latching, extended life, and tungsten contacts available for high current closing. DC, 25-800Hz & air pressure actuation available. Also usable in oil or insulating gas with increased ratings.
-
product
HV Test Load Systems
B-1025-1
Design and manufacture of electronic and electromechanical devices and systems for our customers' special applications has been Ross Engineering Corporation's specialty for 44 years. Among these devices are our High Voltage Test Loads and Resistance/Capacitance Networks designed to simulate radar, communication, and television transmitter loads for testing up to 300kV DC or AC and 200kW. For example, one Test Load System required 4 separate simulated load networks to complete an 8kV, 14kV, 24/6kV, and 34kV high voltage testing system.